ACD-14 FX Digital Clamp-On Digital Multimeter  
 

The ACD 14 FX is the professionals' choice for both HVAC and Electrical applications due to its complete set of measuring features. Its dual display allows viewing amperage and voltage simultaneously. When upgraded to TRMS capability the results are accuracy, reliability and professionalism.
 

ACD-14 FX 400 Amp Digital Clamp-On Digital Multimeter

Features
  • Dual Displays - permits simultaneous reading of Amperage and Voltage.
  • Micro Amps measurement for testing "Flame Sensors".
  • Capacitance to 3000µF.
  • Temperature/ Type-K Thermocouple.
  • AC and DC Voltage to 600V.
  • AC Current to 400A.
  • Resistance to 40MΩ with Continuity Buzzer.
  • Frequency measurement.
  • Diode test.
  • Hold and Maximum reading functions.
  • Accommodates conductors up to 26mm (1.02") in diameter.
  • Auto ranging.
  • Auto power off and low battery indication.
  • Rubber over-moulded case.
  • In rush current.
  • Display 3 3/4 digits 4000-counts, dual LCD displays.
  • Unit supplied with industrial test leads, carrying case, Type-K thermocouple probe, battery and Users manual.

Safety Conformity

Specifications
   

AC Voltage

4.000V, 40.00V, 400.0V, 600V

AC Voltage Accuracy

±1.5% of Reading + 5 digits @ (4.000V, 40.00V, 400.0V)

 

 

DC Voltage

4.000V, 40.00V, 400.0V, 600V

DC Voltage Accuracy

±0.5% of Reading + 3 digits @ (4.000V, 40.00V, 400.0V)

 

 

AC Current

0 to 40.00A, 400A

AC Current Accuracy

±1.9% of Reading + 8 digits*

 

 

AC/DC Micro Amps (using test leads)

400µA, 2000µA

AC Micro Amp Accuracy

±2.0% of Reading + 5 digits

DC Micro Amp Accuracy

±1.5% of Reading + 4 digits

 

 

Resistance (with continuity buzzer)

0 to 400.0Ω, 4.000kΩ, 40.00kΩ, 400.0kΩ

Resistance Accuracy

±0.6% of Reading + 4 digits @ (4.000kΩ, 40.00kΩ, 400.0kΩ)

 

 

Capacitance

500nF, 5.000µF, 50.00µF, 500.0µF, 3000µF

Capacitance Accuracy

±3.5% of Reading + 6 digits

 

 

Frequency (using Jaw or Test Leads)

10Hz to 100kHz

Frequency Accuracy

±0.5% of Reading + 4 digits

 

 

Temperature

-20°C to 300°C (-4°F to 572°F)

Temperature Accuracy

±2.0% of Reading + 6°F

   
*Accuracy specified to 350A continuous, and 400A for 60-second max with 5 minutes cool down interval.
**Added range to indicate instantaneous over-range current values TRMS model ACD-14 TRMS FX accuracy is specified from 10% to 100% of range.
   
General Specifications  

Size
 

190mm (L) x 63mm (W) x 32mm (D)
7.48" (L) x 2.48" (W) x 1.25" (D)

Weight

204g (0.450 lb) approx.

Safety

CE, CAT III 600V

Battery Life

98 hours approx. (in DCV mode)

Warranty

Limited Lifetime

   
Optional Accessories  
   

Part # A47L

Power Line Splitter and Energizer

Part # CT50-1

Amptran 5000A Clamp-On Current Transformer (50:1)

Part # CT50-2

Amptran 3000A Clamp-On Current Transformer (50:1)

Part # A50-1

Deca-Tran 600A Clamp-On Current Transformer (10:1)

Part # ACF-3000AK

3000A Flexible Current Transducer

Part # TMA-K

Temperature Adapter

Part # VRC-320

Set of Push-On Alligator Clips

   
Included Accessories
Set of Test Leads, Type-K Thermocouple, Users Manual and Carrying Case
   
Related Products
ACD-14 TRMS-FX 400 Amp Digital Clamp-On Multimeter
 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Thursday, 15 September 2011