Leda Electronics Logo. Western  Australia's largest distributor of Test Instruments Leda Electronics Showing The Way

 

Page Navigation >

Clamp-On Meter Index >Model ACD-41PQ
Amprobe Test Instruments Logo

Amprobe Clamp-On Meter Heading

 
ACD-41PQ 1000 Amp Power Quality Clamp-on  
 
 

The ACD-41PQ provides a simple and effective way to verify if the electrical system is affected by harmonics. Get complete Power analysis with the ACD-41PQ and increased measuring efficiency with an optional PC interface kit.
 

ACD-41PQ 1000 Amp Power Quality Clamp-on

Features
  • TRMS sensing.
  • Total Harmonics Distortion THD, AC/DC Voltage up to 600V, AC Current up to 1000A.
  • Peak and Data Hold.
  • Temperature
  • Resistance Measurements.
  • Frequency Measurements.
  • Active (W), Reactive (VAR) and Apparent (VA) Power with Power Factor.
  • Optional PC interface capacity (RS-232 KIT2).
  • Audible continuity.
  • Auto Power Off.
  • Automatic Polarity.
  • Low Battery Indication.
  • Measurement Category CAT III 600V (AC/DC)
  • Voltage overload protection for all functions up to 600V AC/DC.
  • Large easy to read LCD display with backlight.
  • Accommodates conductors up to 45mm (1.77") in diameter.

Safety Conformity

 

Specifications
 

True RMS

True RMS sensing

AC Voltage

600.0V

AC Voltage Basic Accuracy

±(0.5% of reading + 5 digits) at 50/60Hz

AC Current

40.0A, 400.0A, 1000A

AC Current Basic Accuracy

±(1.0% of reading + 5 digits) at 50/60Hz

 

 

DC Voltage

600.0V

DC Voltage Basic Accuracy

±(0.5% of reading + 5 digits)

 

 

Resistance

999.9 Ohms

Resistance Basic Accuracy

±(1.0% of reading + 6 digits)

Frequency

5.00Hz to 500Hz

Frequency Basis Accuracy

±(0.5% of reading + 4 digits)

 

 

THD-F

0.0% to 99.9%

THD-F Basic Accuracy

1.5% of Rdg = 6 digits at Fund Frequency

 

 

Active Power (W)

0 to 600.0 kW

Active Power (W) Basic Accuracy

±(2.0% of rdg + 6 digits) at Harmonics Fund to 10th and PF>0.7

Reactive Power (VAR)

0 to 600.0 kVAR

Reactive Power (VAR) Basic Accuracy

±(2.0% of rdg + 6 digits) at Harmonics Fund to 10th and PF>0.7

Apparent Power (VA)

0 to 600.0 kVA

Apparent Power (VA) Basic Accuracy

±(2.0% of rdg + 6 digits) at Harmonics Fund to 10th

 

 

Power Factor

0.10 to 0.99

Power Factor Basic Accuracy

±3 digits at Harmonics Fund to 21th

 

 

Temperature

-50°C to 300°C (-58°F to 572°F)

Temperature Basic Accuracy

±(2.0% of Rdg + 3°C), ±(2.0% of Rdg + 6°F)

 

 

Sampling Rate

1 per second (Power Function)

 

4 per second (Voltage, ACA clamp-on, Hz and Temp Functions)

Polarity

Automatic

Low Battery

Below 2.4V approx.

Transient Protection

6.5kV (1.2/50μs surge)

Pollution

Degree 2

E.M.C.

Meets EN61326 (1997, 1998/A1), EN61000-4-2 (1995), and

 

EN61000-4-3 (1996) an RF field of 3V/m:

 

Specified Accuracy + 45 digits

 

performance above 3V/m is not specified

 
General Specifications
 

Operating Temperature

0°C to 40°C

Storage Temperature

-20°C to 60°C, <80% R.H. (battery removed)

Power Supply

Standard 1.5V 'AAA' size (NEDA 24A or IEC LR03) battery x 2

Power Consumption

10mA typical (Voltage, ACA, Hz and Power Functions)

 

4mA typical (HM and Temperature functions)

Size

224mm (L) x 78mm (W) x 40mm (D)

Weight

224g approx

   

Included Accessories

Users Manual, Batteries, Thermocouple, Carrying Case and Test Leads

 
Optional Accessory
 

RS-232 KIT2 Data recording System

   
 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Thursday, 15 September 2011