| Specifications |
| |
|
AC Voltage |
1.6V to 599.9V |
|
AC Voltage Basic
Accuracy |
±(1.0% of Rdg + 3 digits) |
|
AC Current |
0.0A to 399.9A |
|
AC Current Basic
Accuracy |
±(1.0% of Rdg + 3 digits) |
|
AC Peak Current
(at 1ms response time) |
10A to 800A |
|
AC Peak Current
Basic Accuracy |
±(5.0% of Rdg + 10 digits) |
|
|
|
|
DC Voltage |
1.6V to 599.9V |
|
DC Voltage Basic
Accuracy |
±(1.0% of Rdg + 3 digits) |
|
|
|
|
Resistance |
0 to 499.9Ω,
999Ω, 1999Ω |
|
Resistance
Accuracy |
±(1.0% of Rdg + 5 digits) |
|
Frequency (with
test leads/Jaw) |
40.0Hz to 399.9Hz |
|
Frequency Basic
Accuracy |
±(0.5% of Rdg + 1 digits) |
|
|
|
|
Voltage/Current
Harmonics |
THD, Individual
harmonics 1 to 25 Harmonics |
|
|
1 to 16 at
±(10.0% of Rdg + 5 digits) |
|
Power |
Active, Reactive and
Apparent |
|
Power Factor, Cos
Ø |
0.20 to 1.00 |
|
Power Factor Basic
Accuracy |
±(2.0% of Rdg + 2 digits) |
|
|
|
|
Safety Standards |
EN61010, Class 2,
double reinforced insulation |
|
|
Pollution Level 2 |
|
|
Over Voltage CAT III
600V between terminals and ground |
|
EMC |
This apparatus was
designed in accordance with EMC std's |
|
|
in force and its
compatibility has been tested in accordance |
|
|
with EN61326 (1997) +
A1 (1998) + A2 (2001) |
|
Reference
Temperature |
23°C
±5°C |
|
Operating
Temperature |
5°C
to 40°C |
| |
|
| |
|
|
|
|
|
General Specifications |
|
|
|
|
Power Supply |
2 type 'AAA' 1.5V
batteries |
|
Battery Life |
About 90 hours of
continued measurement |
|
Low Battery
indication |
Symbol is displayed
when battery level is too low |
|
Display |
4 digit LCD with
maximum reading 9999 units plus |
|
|
decimal point and
sign |
|
Sample Rate |
64 samples in 20ms |
|
Conversion Mode |
True RMS |
|
Size |
205mm (L) x 64mm (W)
x 39mm (D) |
|
Weight |
280g approx. |
|
Jaws Opening |
30mm |
|
Maximum Conductor
Size |
30mm |
| |
|
|
Included Accessories |
|
Users Manual, Batteries, Rubber
Holster, Carrying Case and
Test Leads |
| |