ACDC-100 1000 Amp Digital AC/DC Clamp-On Multimeter  
 

Where accuracy, quality, and newest technology meet. The ACDC-100 offers superior AC/DC measurement capabilities, highest product quality and enhanced ergonomics with Red, Rubber,    RibsTH design.
 

ACDC-100 1000 Amp Digital AC/DC Clamp-On Multimeter

Features
  • AC/DC Digital Clamp-On Multimeter.
  • Auto and Manual ranging.
  • Relative zero mode.
  • Auto power 'Off'.
  • MAX capture function for in-rush current measurements (30ms response).
  • Data Hold.
  • Capacitance.
  • Resistance.
  • Diode Test.
  • Audible continuity.
  • Large digital display.
  • Maximum conductor size 50mm (2.0").
  • Rubber over-molded case with built-in probe storage.

Safety Conformity

Specifications
   

AC Voltage Ranges

400.0mV, 4.000V, 40.00V, 400.0V, 600V

AC Voltage Accuracy (4V to 400V range)

±(1.5% of Rdg + 4 digits) (50 to 500Hz)

 

 

AC Current Ranges

400.0A, 800A

AC Current Accuracy (0 to 600A range)

±(1.5% of Rdg + 5 digits) (40 to 100Hz)

 

 

DC Voltage Ranges

400.0mV, 4.000V, 40.00V, 400.0V, 600V

DC Voltage Accuracy (4V to 400V ranges)

±(0.5% of Rdg + 3 digits)

 

 

DC Current Ranges

400.0A, 1000A

DC Current Accuracy (0 to 800A range)

±(1.5% of Rdg + 4 digits)

 

 

Resistance Ranges

400.0Ω, 4.000Ω, 40.00Ω, 400.0kΩ, 40.00MΩ

Resistance Accuracy (4 to 400kΩ range)

±(0.6% of Rdg + 4 digits)

 

 

Capacitance Ranges

500.0nF, 5.000µF, 50.00µF, 500.0µF, 3000µF

Capacitance Accuracy

±(3.5% of Rdg + 6 digits)

   
   
General Specifications
   

Display

3-3/4 digits 4000-count LCD display

Refresh Rate

3 per second nominal

Polarity

Automatic

Low Battery

Below 2.4 volts approx.

Operating Temperature

0°C to 40°C

Relative Humidity

Max R.H. 80% for temperature up to 31°C decreasing

 

linearly to 50% R.H. at 40°C

Storage Temperature

-20°C to 60°C, <80% R.H. (with battery removed)

Temperature Coefficient

Nominal 0.15 x (specified accuracy)/°C at

 

(0°C to 18°C or 28°C to 40°C), or otherwise specified

Sensing

Average sensing

Safety

Meets EN61010-1: 2001; IEC61010-2-032 (2002),

 

EN61010-2-032 (2002), UL61010B-2-032 (2003),

 

CAT III 600 Volts AC/DC

Transient Protection

6.5kV (1.2/50µs surge)

Pollution Degree

2

EMC

Meets EN61326-1

Power Supply

Two 1.5V size 'AAA' (NEDA 24G or IEC R03) batteries

Power Consumption

Typical 11mA for AC amps/DC amps and 2.9mA all

 

other functions

Jaw opening/Conductor size

50mm maximum

Size

227mm (L) x 78mm (W) x 40mm (D)

Weight

290g approx.

   
   

Included Accessories

Test Leads, Batteries (installed), Users Manual, and Carrying Case

 
 
 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Thursday, 15 September 2011