| DC Volts |
| |
Voltage Range |
400mV, 4V, 40V, 400V, 600V |
|
| |
Accuracy |
±(1.0% of Rdg + 2
digits) |
|
| |
Resolution |
0.1mV |
|
| |
Input Impedance |
100MΩ |
400mV Range |
| |
|
10MΩ |
4v Range |
| |
|
9.1MΩ |
40V to 600V Range |
| AC Volts |
| |
Range |
400mV, 4V, 40V, 400V, 600V |
|
| |
Accuracy |
±(2.0% of Rdg + 5
digits) |
400mV (50Hz to 100Hz |
| |
|
±(2.0% of Rdg + 5
digits) |
4V, 40V, 400V, 600V (50Hz to 500Hz |
| |
Resolution |
0.1mV |
|
| |
Input Impedance |
100MΩ |
400mV Range |
| |
|
10MΩ |
4v Range |
| |
|
9.1MΩ |
40V to 600V Ranges |
| |
|
|
|
| DC Current |
| |
Range |
400µA, 4000µA,
40mA, 400mA, 10A |
|
| |
Accuracy |
±(2.0% of Rdg + 2
digits) |
400µA to 400mA Ranges |
| |
|
±(3.0% of Rdg + 3
digits) |
10A Range |
| |
Resolution |
0.1µA |
|
| |
|
|
|
| AC Current (50Hz to 500Hz) |
| |
|
|
|
| |
Range |
400µA, 4000µA,
40mA, 400mA, 10A |
|
| |
Accuracy |
±(2.0% of Rdg + 2
digits) |
400µA to 400mA Ranges |
| |
|
±(3.0% of Rdg + 3
digits) |
10A Range |
| |
Resolution |
0.1µA |
|
| |
|
|
|
| Note: Current measurement 10 Amps for
60 seconds maximum followed by a 10 minute cooling period |
| |
|
|
|
| Resistance |
| |
Ranges |
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ,
40MΩ |
|
| |
Accuracy |
±(1.5% of Rdg + 4
digits) |
400Ω, 4kΩ, 40kΩ, 400kΩ Ranges |
| |
|
±(2.5% of Rdg + 4
digits) |
4MΩ Range |
| |
|
±(5.0% of Rdg + 5
digits) |
40MΩ Range |
| |
Resolution |
0.1Ω |
on 400Ω Range |
| |
|
|
|
| Frequency (auto ranging) |
| |
Ranges |
4kHz, 40kHz, 400kHz |
|
| |
Accuracy |
±(0.1% of Rdg + 3
digits) |
|
| |
Resolution |
1Hz |
|
| |
Sensitivity |
>3.5Vrms |
10Hz to 400Hz Range |
| |
Max. Pulse Width |
>2.5µs |
|
| |
Duty Cycle Limits |
>30% and <70% |
|
| |
|
|
|
| Temperature |
| |
Ranges |
-20°C to 1000°C
(-4°F to 1832°F) |
|
| |
Accuracy |
±(2.0% of Rdg + 4
digits) |
-20°C to 10°C
Range |
| |
|
±(1.0% of Rdg + 3
digits) |
10°C to 200°C
Range |
| |
|
±(2.0% of Rdg + 4
digits) |
-20°C to 10°C
Range |
| |
|
±(3.0% of Rdg + 2
digits) |
200°C to 1000°C
Range |
| |
|
±(2.0% of Rdg + 8
digits) |
-4°F to 50°F
Range |
| |
|
±(1.0% of Rdg + 6
digits) |
50°F to 400°F
Range |
| |
|
±(3.0% of Rdg + 4
digits) |
400°F to 1832°F
Range |
| |
Resolution |
0.1°C/0.1°F |
|
| |
Sensor Type |
Type-K Thermocouple |
|
| |
|
|
|
| RPM |
| |
Range |
600 RPM to 4000 RPM |
|
| |
|
4000 RPM to 12000 RPM |
X10 RPM Range |
| |
Accuracy |
±(2.0% of Rdg + 4
digits) |
|
| |
Resolution |
1 RPM |
|
| |
Effective Reading |
>600RPM |
|
| |
% Duty Cycle |
1.0% to 90% |
|
| |
Resolution |
0.1% |
|
| |
Pulse Width |
>100µs, <100ms |
|
| |
Accuracy |
±(2.0% of Rdg + 5
digits) |
|
| |
|
|
|
| Dwell Angle |
| |
No. of Cylinders |
4, 5, 6, 8 |
|
| |
Angle |
0° to 90° |
4 Cylinders |
| |
|
0° to 72° |
5 Cylinders |
| |
|
0° to 60° |
6 Cylinders |
| |
|
0° to 45° |
8 Cylinders |
| |
Accuracy |
±(2.0% of Rdg + 5
digits) |
|
| |
Resolution |
0.1° |
|
| |
|
|
|
| Continuity |
| |
Audible Indication |
Less than 25Ω |
|
| |
Response Time |
500ms |
|
| |
|
|
|
| Diode Test |
| |
Test Current |
1.0mA (approx.) |
|
| |
Accuracy |
±(3.0% of Rdg + 3
digits) |
|
| |
Resolution |
10mV |
|
| |
Audible Indication |
<0.25V |
|
| |
Open Circuit Volts |
3.0V DC typical |
|
| |
|
|
|
| General Specifications |
| |
|
|
|
| |
Display |
3-3/4 Digit Liquid Display (LCD)
3999-counts |
| |
Display Refresh Rate |
2 times/second, nominal |
| |
Polarity |
Automatic, positive implied, negative
polarity indication |
| |
Overrange |
Yes |
| |
Zero |
Automatic |
| |
Low Battery |
Yes |
| |
Operating Temperature |
0°C to 50°C
at <70% R.H. |
| |
Storage Temperature |
-20°C to 60°C
at <80% R.H. |
| |
Power Supply |
Std 9 Volt battery, NEDA 1604, JIS 006P,
IEC 6F22 |
| |
Battery Life |
150 hours typical with carbon zinc |
| |
Dimensions |
165mm (L) x 78mm (W) x 50mm (D) |
| |
|
6.5" (L) x 3.1" (W) x 1.9" (D) |
| |
Weight |
315g (11.1oz) approx. |