Specifications |
| |
|
|
DC Voltage Ranges |
1000mV, 10V, 100V,
1500V |
|
DC Voltage
Resolution |
0.1mV in 1000mV range |
|
DC Voltage
Accuracy |
±(0.1% of Rdg + 5 digits) |
|
DC Voltage Input
Impedance |
10MΩ |
|
|
|
|
DC Current Ranges |
100μA,
1000μA, 10mA, 100mA, 400mA, 2A |
|
DC Current
Resolution |
0.1μA
in 100μA range |
|
DC Current
Accuracy |
±(0.5% of Rdg + 5 digits) 1000μA
to 400mA range |
|
|
±(1.5% of Rdg + 10 digits) 2A range |
|
|
|
|
AC Voltage True
RMS Ranges |
1000mV, 10V, 100V,
1000V |
|
AC Voltage
Resolution |
0.1mV in 1000mV range |
|
AC Voltage
Accuracy (45Hz to 400Hz) |
±(1.2% of Rdg + 10 digits) 100mV range |
|
AC Voltage
Accuracy (45Hz to 500Hz) |
±(1.2% of Rdg + 10 digits) 10V, 100V ranges |
|
AC Voltage
Accuracy (500Hz to 2kHz) |
±(2.0% of Rdg + 10 digits) 10V, 100V ranges |
|
AC Voltage
Accuracy (45Hz to 1kHz) |
±(2.0% of Rdg + 10 digits) 1000V range |
|
AC Voltage Input
Impedance |
10MΩ |
|
Conversion Type |
True rms, AC couplet
5% to 100% range |
|
Crest Factor |
≤3 |
|
|
|
|
AC Current True
RMS Ranges |
100μA,
1000μA, 10mA, 100mA, 400mA, 2A |
|
AC Current
Resolution |
0.1μA
in 100μA range |
|
AC Current
Accuracy (45Hz to 1kHz) |
±(1.5% of Rdg + 10 digits) 100μA to
100mA range |
|
|
±(2.0% of Rdg + 10 digits) 400mA range |
|
|
±(2.0% of Rdg + 20 digits) 2A range |
|
Conversion Type |
True rms, AC couplet
5% to 100% range |
|
Crest Factor |
≤3 |
|
|
|
|
Resistance Ranges |
1000Ω,
10kΩ, 100kΩ, 1000kΩ, 10MΩ, 40MΩ |
|
Resolution |
0.1Ω
1000Ω range |
|
Resistance
Accuracy |
±(0.5% of Rdg + 8 digits) 1000Ω to
1000kΩ range |
|
|
±(1.0% of Rdg + 10 digits) 10MΩ range |
|
|
±(2.0% of Rdg + 10 digits) 40MΩ range |
|
|
|
|
Capacitance
(Auto/Manual Ranging) |
40nF, 400nF, 4μF,
40μF, 400μF
(3999 counts) |
|
Resolution |
30.01nF |
|
Accuracy |
±(3.0% of Rdg + 10 digits) 40nF, 400μF
ranges |
|
|
±(3.0% of Rdg + 5 digits) 400nF, 40μF
ranges |
|
Test Voltage |
<1V |
|
|
|
|
Temperature Ranges |
-20°C
to 1300°C (-4°F
to 2372°F) 3999-counts |
|
Accuracy |
±(2.0% of Rdg + 4°C) -20°C
to 10°C range |
|
|
±(1.0% of Rdg + 3°C) 10°C
to 200°C range |
|
|
±(2.0% of Rdg + 2°C) 200°C
to 1300°C range |
|
|
±(2.0% of Rdg + 8°C) -4°F
to 50°F range |
|
|
±(1.0% of Rdg + 6°C) 50°F
to 400°F range |
|
|
±(2.0% of Rdg + 4°C) 400°F
to 2372°F range |
|
|
|
|
Continuity Audible
Test Indication |
<40Ω
|
|
Response Time |
<100msec |
| |
|
| General
Specifications |
| |
|
|
Display
|
4 digit LCD,
9999-counts, with annunciators & menu features and 41 segment
Bar-Graph |
|
Display Refresh
Rate |
2.5/sec, nominal,
20/sec for bar-graph |
|
Polarity
Indication |
Automatic |
|
Input Overload
Indication |
Yes |
|
Low Battery
Indication |
Yes (<50 hours
battery life remain, accuracy no longer guaranteed |
|
Operating
Temperature |
0°C
to +50°C (<75% R.H.) |
|
Storage
Temperature |
-20°C
to +60°C (0 to 80% R.H.) battery removed |
|
Fuse |
F2A/1500V fuse (8mm x
65mm), I.R. 30kA |
|
Power Supply |
Std 9V battery, NEDA
1604, JIS 006P, IEC 6F22 |
|
Auto Power Down |
Meter powers down
after 30 minutes approx. of inactivity |
|
Dimensions |
200mm (H) x 102mm (W)
x 59mm (D) |
|
|
7.9" (H) x 4.0" (W) x
2.3" (D) |
|
Weight |
642g (20oz) incl
battery |
|
Case Material |
Flame retardant,
high-impact thermoplastic |
|
Safety |
Meets EN 61010-1 CAT
IV 1000V (1500V DC max), |
|
|
Class II,
EN60529:IP67 |
|
EMC |
Meets EN 61326-1 |
| |
|
|
Included Accessories |
|
Heavy Duty CAT IV 1000V Test leads
with threaded Alligator clips, Batteries (installed),
Hex wrench in holster, Holster with Magne-Grip flex strap,
K-type Thermocouple, Temperature Adaptor and User manual. |
|
| |
| |