Leda Electronics Logo. Western  Australia's largest distributor of Test Instruments Leda Electronics Showing The Way

 

Page Navigation >

Environmental Tester Index > Model SM-70
Amprobe Test Instruments Logo

Amprobe Environmental Tester Heading

 
SM-70 Sound Level Meter  
 

The SM-70 sound level meter has been designed for simple noise surveys and sound level checks. Easy to use for measuring noise in factories, industrial complexes, fire alarms and other alarm systems, and sound system installations.
 

SM-70 Sound Level Meter

Features
  • Measuring level range from 35dB to 130dB.
  • Frequency range 31.5Hz – 8kHz.
  • A and C weightings for checking compliance with safety regulations as well as acoustic analysis.
  • Slow (1 sec) and fast (125ms) response settings to check peak and average noise levels.
  • Maximum hold feature to measure peak sound levels.
  • Over and under range indicator.
  • DC millivolt output for data analysis and recording (10mV/dB).
  • CE, designed to meet IEC651 and ANSI S1- 4 standards.
  • Accessories included are carrying case, 9V battery, screwdriver and instruction manual.

safety Conformity

General Specifications
   

Power Supply

One 9V battery Type MN 1604

Battery Life

50-hours (Alkaline cell) approx.

Operating Temperature

0°C to 40°C  (32°F to 304°F)

Operating Humidity

10 to 90% R.H.

Storage Temperature

-10°c to 60°C (14°F to 140°F)

Storage Humidity

10% to 75% R.H.

 

 

Dimensions

240mm (L) x 68mm (W) x 25mm (D)

Weight

210g including battery

Specifications
   

Standard Applied

According to IEC 651, ANSI S1.4

Frequency Range

31.5Hz to 8kHz

Measuring Level Range

35dB to 130dB

Frequency Weighting

A/C

Microphone

1/2 inch Electric condenser microphone

Display

LCD 4-digits

Display Period

0.5 sec

Digital Display Resolution

0.1dB

 

 

Time Weighting

Fast (125mS), Slow (1 sec)

Level Ranges

Lo: 35db to 100dB and Hi: 65dB to 130dB

Accuracy

±2.0dB (under reference conditions)

Dynamic Range

65dB

 

 

Alarm Function

'OVER' is shown when input is out of range

Maximum Hold

Hold readings, with decay <1dB/3-minutes

Calibration

Electrical calibration with the internal (1kHz sine wave)

AC Output

0.65Vrms at full scale, output impedance 600Ω approx.

DC Output

10mV/dB, output impedance 100Ω approx.

   

Included Accessories

Complete with Carrying Case,9V battery installed, screw-driver, windscreen  and Users Manual.

 
 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.