Fluke 225C and 215C ScopeMeters®
- Specifications |
|
|
| |
 |
| |
|
Bus Health
Test |
Verifies the
electrical parameters of industrial bus systems using automatic
measurement and analysis functions. Next to that, an Eyepattern
mode is provided for visual inspection of signal quality. |
|
Parameter
Classification
Default Values
|
• Well within limits +
'good', gives green tick mark.
• Within specified percentage of the limit values = 'weak',
gives orange
tick-mark.
• Beyond limit values = 'bad', gives red tick mark.
Note: Limits values, as a default, are based on industry
standard for the selected bus type or may be set by the user.
The tolerance band (percentage) taken into account for the
classification 'weak' may be altered by the user. |
|
Bus System
Supported
|
• AS-i (EN 50295, 168
kb/s);
• CAN-bus (ISO-11898, up to 1 Mb/s);
• Modbus 232 (EIA-232 up to 115 kb/s);
• Modbus 485 (EIA-485 up to 10Mb/s);
• Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s);
• Profibus DP (EIA-485 up to 12Mb/s);
• Profibus PA (61158 type 1, 31.25 kb/s);
• Ethernet 10Base2 (coaxial, 10 Mb/s);
• Ethernet 10BaseT (UTP, 10 Mb/s);
• Ethernet 100Base2 (100 Mb/s);
• RS-232 (EIA-232, up to 115 kb/s);
• RS-485 (EIA-485, up to 10 Mb/s). |
|
Modes
|
• Waveform Parameter
analysis with automatic read-out and parameter
validation (good/weak/bad); test limits are based on industry
standards or may be set by the user.
• Eyepattern display mode. |
|
Measured
Parameters (where applicable) |
• bias voltage level
• Signal amplitude
• pulse width or baud rate
• rise-time
• fall time
• jitter
• signal distortion
• noise HF
• Noise LF
• in-band noise |
|
Eyepattern
Display Mode |
Gives waveform
display of bus signals with user selectable persistence of the
display. Time-base, attenuator and persistence settings may be
altered by the user. |
|
Persistence
Modes |
off - short -
medium - long - infinite |
|
| |
| |
 |
| |
|
|
|
Bandwidth |
|
Maximum Real Time Sample Rate |
|
|
Model 215C |
Model 225C |
|
100 MHz |
200 MHz |
|
1 GS/s |
2.5 GS/s |
|
|
Input
Sensitivity |
2 mV to 100
V/div |
|
Time-base
range |
5 ns/div to 2
min/div |
|
Inputs and
digitizers |
2 inputs per
model plus trigger/DMM input |
|
Independently Floating Isolated Inputs |
Up to 1000
volts between inputs, references and ground |
|
Trigger
Types
|
Connect-and-View, Free Run, Single Shot, Edge, Delay, Video,
Selected pulse width and External Dual slope trigger and Event
trigger (n-cycle) |
|
Glitch
Capture
|
up to 3 ns
using Pulse Width triggering; 50 ns peak detected at 5 us/div to
1 min/div |
|
Memory
|
|
|
Display |
144mm full
color LCD with fast update rate |
|
Persistence |
Digital
persistence giving analog oscilloscope-like waveform decay |
|
Waveform
Compare |
Waveform
reference with automatic Pass/Fail testing |
|
Max.
Record Length/Scope Mode |
|
Max
in Scope Record Mode |
|
|
3,000
points per input |
|
27,500
points per input or more (5ms/div ...2min/div) |
|
|
Scope
Measurements |
7 cursor + 30
automatic, including power and Vpwm |
|
True RMS
Multimeter |
5000 counts,
single input |
|
| |
| |
 |
| |
|
Operating
Temperature |
0°C
to 50°C |
|
Storage
Temperature |
-20°C
to +60°C |
|
Operating
Altitude |
3000 meters |
|
| |
| |
 |
| |
|
Electrical
Safety |
1,000V CAT II,
600V CAT III (EN 61010-1) |
|
| |
| |
 |
| |
|
Line Power |
Adapter/Battery/charger included |
|
Battery
Power |
4 hours NiMH |
|
Dimensions |
256mm (L) x
169mm (W) x 64mm (D) |
|
Weight |
2 kg |
|
Warranty |
3-years on
main instrument, 1-year on accessories |
|
| |
| |
|