Current measurement
dc and ac
10Hz to 100Hz










 
Range 40A Resolution: 10mA
  Current Accuracy: 1.5% of reading + 15 digits
  Trigger Level for Inrush: 0.50A
  Trigger Level for Hz Filter OFF: 2.50A
  Trigger Level for Hz Filter ON: 0.50A
Range 400A Resolution: 100mA
  Current Accuracy: 1.5% of reading + 5 digits
  Trigger Level for Inrush: 5.0A
  Trigger Level for Hz Filter OFF: 2.5A
  Trigger Level for Hz Filter ON: 2.5A
Range 2000A; Resolution: 1A
1400A ac rms Current Accuracy: 1.5% of reading + 5 digits
  Trigger Level for Inrush: 5A
  Trigger Level for Hz Filter OFF: 8A
  Trigger Level for Hz Filter ON: 8A
Crest Factor
50/60Hz
 
Range 40A Crest Factor*: 2 @ 33A, 2.4 @ 27A
Range 400A Crest Factor*: 2 @ 330A, 2.4 @ 270A
Range 2000A; Crest Factor*: 2 @ 1000A, 2.4 @ 833A
1400A ac rms Note*: Add 2% to error spec for CF >2
Current Measurement
ac 100.1Hz to 1kHz

 

 

 

 



 

Range 40A Resolution: 10mA
  Current Accuracy >10A: 3.5% of reading + 15 digits
  Trigger Level for Inrush: 0.50A
  Trigger Level for Hz Filter OFF: 2.50A
  Trigger Level for Hz Filter ON: 0.50A
Range 400A Resolution: 100mA
  Current Accuracy >10A: 3.5% of reading + 5 digits
  Trigger Level for Inrush: 5.0A
  Trigger Level for Hz Filter OFF: 2.5A
  Trigger Level for Hz Filter ON: 2.5A
Range 2000A; Resolution: 1A
1400A ac rms Current Accuracy >10A: 3.5% of reading + 5 digits
  Trigger Level for Inrush: 5A
  Trigger Level for Hz Filter OFF: 8A
  Trigger Level for Hz Filter ON: 8A
Voltage
measurement (355 only) dc and ac 10Hz to 100Hz (600V and 1000V ranges have 10% over range to 660V and 1100V respectively)







 
Range 4V Resolution: 10mV
  Accuracy: 1.0% of reading + 10 digits
  Trigger Level for Hz Filter OFF: 0.050V
  Trigger Level for Hz Filter ON: 0.050V
Range 40V Resolution: 10mV
  Accuracy: 1.0% of reading + 5 digits
  Trigger Level for Hz Filter OFF: 0.25V
  Trigger Level for Hz Filter ON: 0.25V
Range 400V Resolution: 100mV
  Accuracy: 1.0% of reading + 5 digits
  Trigger Level for Hz Filter OFF: 6V
  Trigger Level for Hz Filter ON: 6V
Range 600V Resolution: 1V
ac rms Accuracy: 1.0% of reading + 5 digits
  Trigger Level for Hz Filter OFF: 6V
  Trigger Level for Hz Filter ON: 6V
Range 1000V dc Resolution: 1V
  Accuracy: 1.0% of reading + 5 digits
Voltage
measurement (355 only) ac 100.1Hz to 1kHz (600V and 1000V ranges have 10% over range to 660V and 1100V respectively)






 
Range 4V Resolution: 1mV
  Accuracy: 3.0% of reading + 10 digits
  Trigger Level for Hz Filter OFF: 0.050V
  Trigger Level for Hz Filter ON: 0.050V
Range 40V Resolution: 10mV
  Accuracy: 3.0% of reading + 5 digits
  Trigger Level for Hz Filter OFF: 0.25V
  Trigger Level for Hz Filter ON: 0.25V
Range 400V Resolution: 100mV
  Accuracy: 3.0% of reading + 5 digits
  Trigger Level for Hz Filter OFF: 6V
  Trigger Level for Hz Filter ON: 6V
Range 600V Resolution: 1V
ac rms Accuracy: 3.0% of reading + 5 digits
  Trigger Level for Hz Filter OFF: 6V
  Trigger Level for Hz Filter ON: 6V
Ohms measurement (355 only)




 
Range 400Ω Resolution: 0.1Ω
  Accuracy: 1.5% of reading + 5 digits
Range 4kΩ Resolution: 1Ω
  Accuracy: 1.5% of reading + 5 digits
Range 40kΩ Resolution: 10Ω
  Accuracy: 1.5% of reading + 5 digits
Range 400kΩ Resolution: 100Ω
  Accuracy: 1.5% of reading + 5 digits
Continuity beeper
(355 only)
On at ≤30Ω
Off at ≥100Ω
Frequency measurement

 
Measurement Range: 5.0Hz to 1kHz
  Resolution: 0.1Hz (15Hz to 399.9Hz); 1Hz (400Hz to 1kHz)
  Accuracy: 0.2% + 2 counts (5.0Hz to 100Hz)
  Accuracy: 0.5% + 5 counts (100.1Hz to 1kHz)
  Trigger level: Refer to current and voltage tables
 
 
General Specifications
Batteries Six 1.5V 'AA' NEDA 15 A or IEC LR6 batteries
Battery life 100 hours (typical usage, backlight off)
Test leads Rated to 1000V
Weight 814g (1.8 lb)
Jaw size 58mm (2.28 in)
Dimensions 300mm (L) x 98mm (W) x 52mm (D) (12" (L) x 3.75" (W) x 2" (D)
Safety rating IEC 61010-2-032, 600V CAT IV, 1000V CAT III
 
 
Environmental Specifications
Operating temperature 0°C to +50°C (32°F to +122°F)
Storage temperature -20°C to +60°C (-4°F to 140°F)
Operating humidity 0 to 95% (non-condensing)
Operating altitude 2000 meters
Storage altitude 10,000 meters
IP rating 42 (indoor use only)
Drop test requirements 1 meter
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m,
performance criteria B, EN 61325
Temperature coefficients
 
Current: 0.1% of reading per °C outside 22°C to 24°C
Voltage: 0.1% of reading per °C outside 22°C to 24°C
 
 
 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Thursday, 15 September 2011