| Temperature Range |
-30°C to
900°C (-25°F
to 1600°F) |
Resolution
|
0.1°C of
reading up to 900°C
0.2°F of reading up to 999.8°F |
Optical Resolution
(Distance to spot size) |
60:1 Standard focus
50:1 Close focus |
| User Selectable |
°C
or °F |
Minimum Measurement
Diameter
|
19mm (0.76") Standard
focus
6mm (0.24") Close focus |
| Laser Sighting |
Three point coaxial
laser |
Laser Power
|
Class 2 (II) operation;
Output <1mV,
wavelength 630-670nm |
| Adjustable Emissivity |
Digitally adjustable
from 0.10 to 1.0 by 0.01 |
Accuracy
(assumes ambient operating temp of 23°C
(73°F) to 25°C
(77°F)) |
0.75% of reading
±1% of reading or
±0.75°C
(±1.5°F),
whichever is greater |
| Response Time |
250mSec (95% of
reading) |
| Repeatability |
±0.5% of reading or
±1°C
(±2°F),
whichever is greater |
| Spectral Response |
8µm to
14µm |
| Relative Humidity |
10% to 90% RH
non-condensing, at <30°C (86°F) |
| Tripod Mount |
1/4 inch 20 UNC
threading |
| Battery Power |
2 AA batteries |
| Battery Life |
13 hours with laser and
backlight on 50% |
| Display Hold |
7 seconds |
| Backlit LCD Display |
Yes |
| Operating Temperature |
0°C
to 50°C (32°F
to 120°F) |
| Storage Temperature |
-20°C
to 50°C (-25°F
to 120°F) |
| Warranty |
2 years |
| MAX/MIN Temperatures |
Yes |
| Recall Last Reading |
Yes |
| Audible/Visible HI
Alarm |
Yes |
| Bargraph Display |
Yes |
| Size |
200mm x 170mm x 55mm |
| Weight |
0.472kg |