Leda Electronics Logo. Western  Australia's largest distributor of Test Instruments Leda Electronics Showing The Way

 
 
Fluke Test Instruments Logo

Fluke Process Calibration Instruments

 
Fluke 718 Series Pressure Calibrator  - Specifications  
 
 
Fluke 718 Pressure Calibrator Series Technical Specifications
Fluke 718 Series

Measure Pressure

 

Accuracy:

 

Functions:

 

Note:

(Internal sensor)

0.05% full scale

Zero, Min, Max, Hold, Damp

dry air, non-corrosives only

Fluke 718 1G

Range:

 

Resolution:

 

Over Pressure:

 

Functions:

-1 to 1 PSI, -68.9 mbar to 68.9 mbar  (-6.89 kPa to 6.89 kPa)

0.0001 PSI, 0.001 mbar, 0.0001 kPa

5 x full scale

Zero, Min, Max, Hold, Damp

Fluke 718 30G

Range:

 

Resolution:

 

Over Pressure:

 

Functions:

-12 to 30 PSI, (-850 mbar to 2 bar, -85 to 206.84 kPa)

0.001 PSI, 0.1 mbar, 0.01 kPa

5 x full scale

Zero, Min, Max, Hold, Damp

Fluke 718 100G

Range:

 

Resolution:

 

Over Pressure:

 

Functions:

-12 to 100 PSI, (-850 mbar to 7 bar, -85 to 689.48 kPa)

0.01 PSI, 0.1 mbar, 0.01 kPa

2 x full scale

Zero, Min, Max, Hold, Damp

Fluke 718 300G

Range:

 

Resolution:

 

Over Pressure:

 

Functions:

-12 to 300 PSI, (-850 mbar to 20 bar, -85 to 2068.42 kPa)

0.01 PSI, 1 mbar, 0.1 kPa

375 PSI, 25 bar

Zero, Min, Max, Hold, Damp

Fluke 718 Series using 700 Series
Pressure Modules

Range:

 

 

Resolution:

 

Accuracy:

 

Functions:

   
 

(via pressure module connector using optional Pressure Module)

29 pressure modules, 0 - 1 in H20 to 10,000 PSI, 2.5 mbar to 700

bar. Over pressure per pressure module specifications.

Per pressure module specs

To 0.025% of full span, per pressure module specifications

Zero, Min, Max, Hold, Damp

Note: media compatibility per pressure module specs.
Fluke 718 Series via Built in Pump
   
 

Range:

 

 

 

 

Loop Power

 

 

Accuracy:

 

 

 

 

mA Measure

 

 

Range:

 

Resolution:

 

Accuracy

 
 

-12 PSI or -850 mbar to full scale Supported Pressure Units; psi,

in H20 (4°C), in H20 (20°C), cm H20 (20°C), bar, mbar, kPa, in Hg,

mmHg, kg/cm

 

 ±10%

Note: Drive; 20mA into 1000 for battery > 6.8V; 700 for battery

        5.8 to 6.8V

 

0 mA to 24 mA

0.0001 mA

0.015% + 1 count

 
 
Fluke 718 Series General Specifications
Maximum voltage 30 volts: Non-operating
Operating temperature -10șC to 55șC
Non-operating temperature -40șC to 60șC
Relative humidity (% RH operating without condensation) 95% (10șC to 30șC); 75% (30șC to 40șC);
45% (40șC to 50șC); 35% (50șC to 55șC)
Operating altitude 3,000m max
Vibration Random, 2g, 5-500 Hz
Shock 1m drop test
Vibration Random, 2g, 5Hz - 500Hz
Safety CSA C22.2 No. 1010.1:1992
EMC EN50082-1: 1992 and EN55022: 1994 Class B
Power Two 9V battery ANSI/NEDA 1604A or IEC 6LR61
Battery life 4 to 20 hours typical, depending on functions used
Size 216 mm (L) x 94mm (W) x 66mm (D)
(8.5 in X 3.72 in x 2.6 in)
Weight 992g (35 oz)
Display: LCD, 5 digit pressure and current simultaneous
Warranty: 3 years (one year on pressure pump)
 
Note: For use with non-corrosive gasses

 

 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Thursday, 15 September 2011