Leda Electronics Logo. Western  Australia's largest distributor of Test Instruments Leda Electronics Showing The Way

 
 
Fluke Test Instruments Logo

Fluke Process Calibration Instruments

 
Model 725 Multifunction Calibrator - Specifications  
 
 
Model 725 Summary Specifications
(18C to 28C for one year) *
Voltage (max load, 1 mA) 0 to 100 mV:
Resolution: 0.01 mV
Accuracy:.02% Rdg + 2 LSD
0 to 10V (source):

Resolution: 0.001V
Accuracy:.02% Rdg + 2 LSD
0 to 30V (measure):

Resolution: 0.001V
Accuracy:.02% Rdg + 2 LSD
mA (max load, 1000W) 0 to 24 mA:
Resolution:0.001 mA
Accuracy: .02% Rdg + 2 LSD
mV (TC terminals) -10.00 mV to +75.00 mV:
Resolution: .01 mV
Accuracy: .025% Rdg + 1 LSD
Resistance 0W to 3200W (measure):
Resolution: 0.01W to 0.1W
Accuracy: 0.10W to 1.0W
15W to 3200W (source):

Resolution: 0.01W to 0.1W
Accuracy: 0.10W to 1.0W
Frequency ** 1 CPM to 10 kHz (measure):
Resolution: 5 digits
Accuracy: 0.05% Rdg + 1 LSD
2.0 to 1000.0 CPM (source):

Resolution: 0.1 CPM
Accuracy: ±.05%
1 to 1000 Hz (source):

Resolution: 1 Hz
Accuracy: ±.05%
1.0 to 10.0 kHz (source):

Resolution: 0.1 kHz
Accuracy: ±.25%
Loop Supply 24V dc:
Resolution: N/A
Accuracy: 10%
 
*Temperature coefficient, -10°C to 18°C, 28°C to 55°C,±.005% of range per °C.
**(For frequency source, waveform is 5V p-p square wave, -0.1V offset)
 
 
RTD and Thermocouple Specifications
 
Thermocouple Accuracy*
J -200 to 0ºC:
Accuracy: 1.0ºC
0 to 1200ºC:

Accuracy: 0.7ºC
K -200 to 0ºC:
Accuracy: 1.2ºC
0 to 1370ºC:

Accuracy: 0.8ºC
T -200 to 0ºC:
Accuracy: 1.0ºC
0 to 400ºC:

Accuracy: 0.8ºC
E -200 to 0ºC:
Accuracy: 0.9ºC
0 to 950ºC:

Accuracy: 0.7ºC
R -20 to 0ºC:
Accuracy: 2.5ºC
0 to 500ºC:

Accuracy: 1.8ºC
500 to 1750ºC:

Accuracy: 1.4ºC
S -20 to 0ºC:
Accuracy: 2.5ºC
0 to 500ºC:

Accuracy: 1.8ºC
500 to 1750ºC:

Accuracy: 1.5ºC
B 600 to 800ºC:
Accuracy: 2.2ºC
800 to 1000ºC:

Accuracy: 1.8ºC
1000 to 1800ºC:

Accuracy: 1.4ºC
L -200 to 0ºC:
Accuracy: 0.85ºC
0 to 900ºC:

Accuracy:0.7ºC
U -200 to 0ºC:
Accuracy: 1.1ºC
0 to 400ºC:

Accuracy: 0.75ºC
N -200 to 0ºC:
Accuracy: 1.5ºC
0 to 1300ºC:

Accuracy: 0.9ºC
*(Accuracy specifications include 0.2°C cold junction uncertainty)
 
Thermocouple Resolution
J, K, T, E, L, N, U 0.1ºC, 0.1ºF
B, R, S 1ºC, 1ºF
 
 
RTD Ranges and Accuracy
Ni 120
-80ºC to 260ºC:
Measure: 0.2ºC
Source: 0.2ºC
Pt 100 - 385 -200ºC to 800ºC:
Measure: 0.33ºC
Source: 0.33ºC
Pt 100 - 3926 -200ºC to 630ºC:
Measure: 0.3ºC
Source: 0.3ºC
Pt 100 - 3916
(JIS)
-200ºC to 630ºC:
Measure: 0.3ºC
Source: 0.3ºC
Pt 200 - 385 -200ºC to 250ºC:
Measure: 0.2ºC
Source: 0.2ºC

250ºC to 630ºC:
Measure: 0.8ºC
Accuracy: 0.8ºC

Pt 500 - 385 -200ºC to 500ºC:
Measure: 0.3ºC
Source: 0.3ºC

500ºC to 630ºC:
Measure: 0.4ºC
Accuracy: 0.4ºC

Pt 1000-385 -200ºC to 100ºC
Measure: 0.2ºC
Source: 0.2ºC

100ºC to 630ºC
Measure: 0.3ºC
Source: 0.2ºC

 
 
RTD Resolution
RTD 0.1ºC, 0.1ºF
 
 
Model 725 Mechanical and General Specifications
Maximum voltage 30V
Storage Temperature -20ºC to 71ºC
Operating Temperature -10ºC to 55ºC
Relative Humidity 90% (10ºC to 30ºC); 75% (30ºC to 40ºC);
45% (40ºC to 50ºC); 35% (50ºC to 55ºC)
Vibration Random, 2g, 5-500 Hz
Safety CSA C22.2 No. 1010.1:1992
EMC EN50082-1:1992 and EN55022:1994 Class B
Size 96 x 200 x 47 mm (3.8 x 7.9 x 1.9 inches)
Weight 650g (23oz)
Battery Four AA alkaline batteries. Battery life: 25 hours typical
Warranty Three years

 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Thursday, 15 September 2011