Model 902 AC/DC True-Rms HVAC Clamp Meter - Specifications  
 
 
Fluke Model 902 True-Rms HVAC Clamp Meter Specifications
Voltage DC

Range:

0 to 600.0V

Accuracy:

1% ±5 counts
Voltage AC (True RMS)

Range:

0 to 600.0V

Accuracy:

1% ±5 counts (50/60Hz)
Current AC (True RMS)

Range:

0 to 600.0A

Accuracy:

2% ±5 counts (50/60Hz)
Current DC

Range:

0 to 200.0µA

Accuracy:

1% ±5 counts
Resistance

Range:

0 to 9999Ω

Accuracy:

1.5% ±5 counts
Continuity ≤ 30Ω
Temperature* (Type K Thermocouple)

Range:

-10°C to 400°C (-14°F to 752°F)

Accuracy:

±1% + 0.8°C (±1% + 1.5°F) typical

Range:

-40°C to 10°C (-40°F to 14°F)

Accuracy:

±5.0% + 1.5°C (±5.0% + 3.3°F) typical
Capacitance

Range:

1 to 1000µF

Accuracy:

1.9% ±2 counts
 
*Error does not include Type 'K' Thermocouple errors.
 
 
Model 902 True-rms HVAC Clamp Meter Mechanical and General Specifications
 
Weight 7kg (1.5 lbs)
Dimensions 27.3cm x 10.8cm x 6.2cm  (10.75" x 4.25" x 2.44")
Battery Type Two Type 'AA' Alkaline Batteries
 

 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Thursday, 15 September 2011