i30s AC/DC Current Clamp
for use with DMM's,
Oscilloscopes, ScopeMeters and Power Quality Analyzers.
|
 |
 The i30s current clamp is based
on Hall Effect technology for use in measurement of both DC and AC
current. The i30s may be used in conjunction with oscilloscopes and other
suitable recording instruments for accurate non-intrusive current
measurements. |
|
| |
 |
|
Current Range |
20 Amps AC rms
or DC |
|
Measuring
Range |
±30 Amps |
|
Output
Sensitivity |
100mV/A |
|
Accuracy (at
25°C) |
±1% of reading
±2mA |
|
Load
Impedance |
> 100KΩ |
|
Conductor
Position Sensitivity |
±1% relative to
center reading |
|
Frequency
Range |
DC to 100kHz
(-0.5db) |
|
Phase Shift
below 1kHz |
< 2 degrees |
|
Temperature
Coefficient |
±0.01% of
reading/°C |
|
Power Supply |
9 volt Alkaline,
MN1604/PP3, 30 hours, low battery indicator. |
|
Working
Voltage |
300 Volts AC rms
or DC (see Safety Standards section) |
|
| |
| |
 |
|
Safety
Standards |
BS EN 61010-1:
2001
BS EN 61010-2-203: 2002
BS EN 61010-031: 2002
300 Vrms, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 300 volts
ACrms or DC and frequencies below 1kHz. |
|
EMC Standards |
EN 61326: 1998
+A1, A2, and A3 |
|
| |
| |
 |
|
Maximum
Conductor Size |
19mm diameter |
|
Output
Connection |
Safety BNC
connector, supplied with safety 4mm adapter |
|
Output Zero |
Manual adjust
via thumbwheel |
|
Cable length |
2 meters |
|
Operating
Temperature Range |
0°C to +50°C |
|
Storage
Temperature Range |
-20°C to +85°C (with battery removed) |
|
Operating
Humidity |
15% to 85%
(non-condensing) |
|
Weight |
250g |
|
| |