MBX Clamp 5A/50A Current Clamp  
 
Fluke Model MBX Clamp 5A/50A Current Clamps. Four precision dual range current clamps (5 amp and 50 amp) for secondary current transformer applications.

Four precision dual range current clamps (5 amp and 50 amp) for secondary current transformer applications.

Expand the capabilities of the Fluke 1735 and 1740 Series Loggers with these dual-range current clamps. The accessory includes four precision clamps that are automatically detected and scaled by the instrument when attached.

 

 
Model MBX 5A/50A Current Clamp Specifications

Electrical Characteristics

Nominal current in:

Overload:

Conductor position influence:

Error due to adjacent conductor:

Phase shift at 2kHz at 200A:

Frequency range:

Temperature coefficient:

Working voltage (see safety section):

Order reference:

 

 

50Amps AC rms

up to 100Amps rms

<0.5% of range at 50/60 Hz

less than or equal to 15mA/A at 50Hz

< ±1 degree

40 Hz to 10 kHz (-3 dB)

0.015% of range /°C

600 Volts AC rms or DC

single-phase: EP0442A
three-phase: EP0452A
three-phase+N: EP0453A

Accuracy

Primary current 0.125A to 2.5A:
 

Primary current 2.5A to 12.5A:
 

Primary current 12.5A to 25A:
 

Primary current 25A to 50A:
 

 

Operating error in % of reading: ±2.5%
Phase Shift: not specified

Operating error in % of reading: ±1.5%
Phase Shift: <2°

Operating error in % of reading: ±0.5%
Phase Shift: <0.5°

Operating error in % of reading: ±0.5%
Phase Shift: <1°

General Characteristics

Maximum conductor size:

Cable length:

Operating temperature range:

Storage temperature range:

Operating humidity:

Weight per clamp:

 

15mm diameter, bus bar 15mm x 17mm

2 meters

-10°C to +55°C

-20°C to +70°C

15% to 85% R.H. (non condensing)

175 gms

Reference Conditions

Environmental temperature range:

Humidity:

Current:
 

Load impedance for voltage output:

 

+18°C to +26°C

20% to 75% R.H.

sinusoidal waveform, 48 to 65Hz, distortion factor: <1%, no DC component

greater than or equal to 1m ohm, <100pF

Safety Standards

IEC/EN61010-1: 2001
IEC/EN61010-2-032
IEC/EN61010-2-031

Safety

600V CAT III, pollution degree 2
The application of the clamps on uninsulated conductors is limited to 600V AC rms or DC to ground and frequencies below 1kHz

EMC Standards

EN61326-1: 1997/A1: 1998

Dimensions

102mm x 42.5mm x 23.5mm

 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Thursday, 15 September 2011