| Display |
Color transmissive LCD 320 x
240 pixels (70mm diagonal) with two level backlight. |
| Battery Power (qty 6) |
Battery. 1.5 volt Alkaline AA
MN 1500 or IEC LR6 |
| Battery Life (typical) |
>10 hours (backlight on full)
> 12 hours (backlight reduced) |
| Battery Eliminator (#BE345) |
Input: 110/230V 50/60 Hz
Output: 15V DC 300mA |
Dimensions
|
300mm (L) x 98mm (W) x 52mm
(D)
12" (L) x 3.75" (W) x 2" (D) |
| Weight (including
batteries) |
820g (1.8 lb) |
| Jaw Opening |
60mm |
| Jaw Capacity |
58mm diameter |
| Cleaning |
The unit can be cleaned with
an Isopropanol impregnated cloth. Do not use abrasives or other
solvents. |
|
| |
| |
 |
|
Ambient Conditions (for indoor use
only) |
| Reference Conditions |
All accuracies stated at 23°C
±1°C (73.4°F
±1.8°F) |
| Operating Temperature |
0°C
to 50°C (32°F
to 122°F) |
| Temperature Coefficient of
Current |
≤±0.15% of reading per
°C |
| Temperature Coefficient of
Voltage |
≤±0.15% of reading per
°C |
| Maximum Relative Humidity |
80% for temperatures up to 31°C
(87°F) decreasing linearly to 50%
relative humidity at 40°C (104°F) |
| Maximum Operating Altitude |
2000 m |
|
| |
| |
 |
Safety
|
IEC 61010-1 600V CAT. IV
double or reinforced insulation, Pollution Degree 2. |
| Protection |
IP40; EN 60529 |
Maximum Safe Working
Voltages
|
| Current Measurement: |
600V ACrms or DC between uninsulated
conductor and ground. |
| Voltage Measurement: |
600V ACrms or DC between either
input terminal and ground, or 825V between energised phase
voltages (delta power configuration). |
|
|
| |
| |
 |
| Emission |
IEC/EN 61326-1: 1997 Class A |
| Immunity |
IEC/EN 61326-1: 1997 Annex C
Performance Criterion B |
|
| |
| |
 |
Accuracies
|
All accuracies stated at 23°C
±1°C (73.4°F
±1.8°F). See Ambient condition
specifications for temperature coefficients. |
|
| |
| |
 |
|
Current Measurement (DC, DC rms,
AC rms) |
| Measuring Range |
0 to 2000 Amps DC or 1400 Amps
AC rms |
| Autorange Facility |
40A/400A/2000A |
Resolution
|
10mA in 40 Amp range
100mA in 400 Amp range
1 Amp in 2000 Amp range |
| Accuracy |
| DC
Current > 10A: |
±1.5% of
reading ±5 digits |
| DC rms
Current <10A: |
±0.2 A |
| |
|
| AVG
Current >10A: |
±3% of
reading ±5 digits |
| Current
<10A: |
±0.5 A |
| |
|
| Peak
Current >10A: |
±5% of
reading ±5 digits |
| Current
<10A: |
±0.5 A |
| |
|
| AHr
Current >10A: |
±2% of
reading ±5 digits |
| Current
<10A: |
±0.5 AHr |
| |
|
|
Crest
Factor |
|
| 1.1 ≤
CF <3: |
±3% of
reading ±5 digits |
| 3 ≤ CF
<5: |
±5% of
reading ±5 digits |
|
Resolution: |
0.01 |
| |
|
|
Ripple |
|
| 2% ≤
RPL <100%: |
±3% of
reading ±5 digits |
| 100% ≤
RPL <600%: |
±5% of
reading ±5 digits |
|
Resolution: |
0.1% |
| ldc >
5A, lac> 2A |
|
|
|
| Note: |
All measurements DC and 15Hz to 1kHz
|
| |
Maximum overload 10,000 A or rms x
frequency < 400,000 |
| |
Amps rms is a true-rms measurement (AC +
DC) |
|
| |
| |
 |
|
Voltage Measurement (DC, DC rms,
AC rms) |
| Measuring Range |
0 to 825 Volts DC or AC rms |
| Autorange Facility |
4V/40V/400V/750V |
| Resolution |
| 1mV |
in 4 volt range |
| 10mV |
in 40 volt range |
| 100mV |
in 400 volt range |
| 1V |
in 750 volt range |
|
| Accuracy |
| DC and DC rms |
|
| Volt
>1V: |
±1% of
reading ±5 digits |
| Volt
<1V: |
±0.02 V |
| |
|
| AVG
Voltage >1V: |
±3% of
reading ±5 digits |
| Voltage
<1V: |
±0.03 V |
| |
|
| Peak
Voltage >1V: |
±5% of
reading ±5 digits |
| Voltage
<1V: |
±0.03 V |
| |
|
| Crest
Factor |
|
| 1.1 ≤
CF <3: |
±3% of
reading ±5 digits |
| 3 ≤ CF
<5: |
±5% of
reading ±5 digits |
|
Resolution: |
0.01 |
| |
|
|
Ripple |
|
| 2% ≤
RPL <100%: |
±3% of
reading ±5 digits |
| 100% ≤
RPL <600%: |
±5% of
reading ±5 digits |
|
Resolution: |
0.1% |
| ldc >
5A, lac> 2A |
|
|
|
| Note: |
All measurements DC and 15Hz to 1kHz
|
| |
Maximum overload 10,000 A or rms x
frequency < 400,000 |
| |
Amps rms is a true-rms measurement (AC +
DC) |
|
| |
| |
 |
| Total Harmonic Distortion
(THD) |
| 1% ≤THD
<100%: |
±3% of
reading ±5 digits |
| 100%
≤THD <600%: |
±5% of
reading ±5 digits |
|
Resolution: |
0.1% |
|
| Distortion Factor (DF) |
| 1% ≤DF
<100%: |
±3% of
reading ±5 digits |
|
Resolution: |
0.1% |
| H02
≤Vharm <H13: |
±5% ±2 digits |
| H13
≤Vharm <H30: |
±10% ±2 digits |
|
|
| Note: |
All measurements up to 30th harmonic (40th
harmonic for 15Hz to 22Hz) |
| |
Frequency range of fundamental Fo
15Hz to 22 Hz and 45 Hz to 65 Hz Vacrms >1V |
|
| |
| |
 |
|
Watts Measurement (single- and
three-phase) (DC, DC rms, AC rms) |
| Measuring Range |
0 to 1650 kW DC or 1200 kW AC |
| Autoranging Facility |
4 kW, 40 kW, 400 kW, 1650 kW |
| Resolution |
| 1 W |
in 4kW range |
| 10 W |
in 40 kW range |
| 100 W |
in 400 kW range |
| 1 kW |
in 1200 kW range |
|
| Accuracy |
2.5% of reading ±5 digits
W (single phase) <2 kW ±0.08 kW
W (three phase) <4 kW ±0.25 kW |
|
| |
| |
 |
|
VA Measurement (single- and
three-phase) (DC, DC rms, AC rms) |
| Measuring Range |
0 to 1650 kVA DC or 1200 kVA
AC |
| Autoranging Facility |
4 kVA, 40 kVA, 400 kVA, 1650
kVA |
| Resolution |
| 1 VA |
in 4 kVA range |
| 10 VA |
in 40 kVA range |
| 100 VA |
in 400 kVA range |
| 1 kVA |
in 1200 kVA range |
|
| Accuracy |
| VA >2
kVA: |
2.5% of
reading ±5 digits |
| VA
<2kVA: |
±0.08 kVA |
|
|
| |
|
VAR Measurement (single- and
three-phase) |
| Measuring Range |
0 to 1250 kVAR |
| Autoranging Facility |
4 kVAR, 40 kVAR, 400 kVAR,
1200 kVAR |
| Resolution |
| 1 VAR |
in 4 kVAR range |
| 10 VAR |
in 40 kVAR range |
| 100 VAR |
in 400 kVAR range |
| 1 kVAR |
in 1200 kVAR range |
|
| Accuracy |
| VAR >4
kVAR: |
2.5% of
reading ±5 digits |
| VAR
<4kVAR: |
±0.25 kVAR |
|
| Power Factor Range |
0.3 <PF <0.99 |
|
| |
| |
 |
|
Power Factor (single- and
three-phase) |
| Measuring Range |
0.3 capacitive to 1.0 and 1.0
to 0.3 inductive
(72.5° capacitive to 0°
and 0° to 72.5°
inductive) |
| Resolution |
0.001 |
| Accuracy |
±3° |
| Frequency Range |
15Hz to 1kHz |
|
| |
| |
 |
|
Displacement Power Factor (single- and
three-phase) |
| Measuring Range |
0.3 capacitive to 1.0 and 1.0
to 0.3 inductive
(72.5° capacitive to 0°
and 0° to 72.5°
inductive) |
| Resolution |
0.001 |
| Accuracy |
±3° |
| Frequency Range |
15Hz to 22 Hz and 45Hz to 65 Hz |
|
| |
| |
 |
|
Kilowatt Hour (kWHr) |
| Measuring Range |
40,000 kWHr |
| Autoranging Facility |
4 kWHr, 40 kWHr, 400 kWHr,
4000 kWHr, 40,000 kWHr |
| Resolution |
| 1 WHr |
in 4 kWHr range |
| 10 WHr |
in 40 kWHr range |
| 100 WHr |
in 400 kWHr range |
| 1 kWHr |
in 4,000 kWHr range |
| 10 kWHr |
in 40,000 kWHr range |
|
| Accuracy |
| kWHr >2
kWHr: |
3% of
reading ±5 digits |
| kWHr
<2kWHr: |
±0.08 kWHr |
|
All
Watts/VA/VAR/PF
Measurements |
|
Frequency Range: |
DC and 15
Hz to 1 kHz |
| Current
Range: |
10 Amp to
1400 Amps rms |
| Voltage
Range: |
1 Volt to
825 Volts rms |
| Maximum
Input: |
825 Volts
rms/1400 Amps rms |
| Maximum
Overload: |
1000 Volts
rms/10,000 Amps |
|
|
| |
| Note: |
All measurements DC and 15Hz to 1 kHz. |
| |
Maximum overload 10,000 Amps or rms x
frequency <400,000 |
|
| |
| |
 |
|
Frequency Measurement (from
current or voltage sources) |
| Measuring Range |
15 Hz to 1 kHz |
| Resolution |
0.1 Hz |
| Accuracy |
| 15 Hz to 22 Hz |
±0.5% of reading |
| 40Hz to 70 Hz |
±0.5% of reading |
| 15 Hz to 1000 Hz |
±1.0% of reading |
|
| Current Range |
10 Amps to 1400 Amps rms |
| Voltage Range |
1 Volt to 825 Volts rms |
|
| |
| |
 |
| Current Measurement |
| Ranges: |
10A/20A/40A/100A/200A/400A/1000A/ |
| |
2000A |
| Resolution: |
|
1 Amp |
in 40
Amp range |
|
10
Amp |
in
400 Amp range |
|
50
Amp |
in
2000 Amp range |
|
| Accuracy: |
±3% of
reading ±1 pixel |
| Max Overload: |
10,000 Amps |
|
| Voltage Measurement |
| Ranges: |
4V/10V/20V/40V/100V/200V/400V/ |
| |
1000V |
| Resolution: |
|
100mV |
in 4
Volt range |
|
1
Volt |
in 40
Volt range |
|
10
Volt |
in
400 Volt range |
|
31.25
Volt |
in
1000 Volt range |
|
| Accuracy: |
±2% of
reading ±1 pixel |
| Max Overload: |
1000 Volts
rms |
| Frequency Range: |
DC and 15 Hz to 600 Hz |
|
| Time Base |
2.5 ms, 5 ms, 10 ms, 25 ms, and 50 ms/div |
| Refresh Rate |
0.5 seconds |
| Maximum Sampling Rate |
15.625 kHz |
|
| |
| |
 |
| Ranges |
40A, 400A and 2000 Amp |
| Resolution |
|
10 mA |
in 40 Amp
range |
|
100 mA |
in 400 Amp
range |
|
1 Amp |
in 2000 Amp
range |
|
| Accuracy |
| Current >10A: |
±5% of
reading ±1 pixel |
| Current
<10A: |
±0.5A |
| All
measurements DC and 15 kHz to 1 kHz |
|
| Maximum Overload |
Maximum overload 10,000 A or rms x frequency
<400,000 Amps rms is a true-rms measurement (AC + DC) |
| Capture Time |
1s, 3s, 10s, 30s, 100s, and
300 seconds |
| Maximum Sampling Rate |
15.625 kHz |
|
| |
| |
 |
| Interface |
USB interface to a PC |
| Software |
Power Log software for
download, analysis and reporting |
| Upgrade Utility |
345 Upgrade Utility for installing a new
firmware version |
|
| |
| |
 |
| Logging Areas |
Three areas that can be used
individually or combined into one large area. |
| Averaging Periods |
1s, 2s, 5s, 10s, 30s, 1 min, 5
min, 10 min, 15 min and custom |
|
| |
| |
 |
| Volts and Current Mode |
| Average Time |
Logging Time (1 area) |
| 1 sec |
1 h 49 m |
| 2 sec |
3 h 38 m |
| 5 sec |
9 h 6 m |
| 10 sec |
18 h 12 m |
| 30 sec |
2 d 6 h 36 m |
| 1 min |
4 d 13 h 12 m |
| 5 min |
22 d 18 h 0 m |
| 10 min |
45 d 12 h 0 m |
| 15 min |
68 d 6 h 0 m |
| |
|
| |
Logging Time (3 areas) |
| 1 sec |
5 h 12 m |
| 2 sec |
10 h 24 m |
| 5 sec |
1 d 2 h 00 m |
| 10 sec |
2 d 4 h 00 m |
| 30 sec |
6 d 12 h 1 m |
| 1 min |
13 d 0 h 12 m |
| 5 min |
65 d 0 h 15 m |
| 10 min |
130 d 0 h 30 m |
| 15 min |
195 d 0 h 45 m |
|
| V & A Harmonics Mode |
| Average Time |
Logging Time (1 area) |
| 1 sec |
1 h 34 m |
| 2 sec |
1 h 8 m |
| 5 sec |
2 h 52 m |
| 10 sec |
5 h 44 m |
| 30 sec |
17 h 13 m |
| 1 min |
1 d 10 h 26 m |
| 5 min |
7 d 4 h 10 m |
| 10 min |
14 d 8 h 20 m |
| 15 min |
21 d 12 h 30 m |
| |
|
| |
Logging Time (3 areas) |
| 1 sec |
1 h 38 m |
| 2 sec |
3 h 16 m |
| 5 sec |
8 h 11 m |
| 10 sec |
16 h 23 m |
| 30 sec |
2 d 1 h 11 m |
| 1 min |
4 d 2 h 23 m |
| 5 min |
20 d 11h 25 m |
| 10 min |
81 d 0 h 50 m |
| 15 min |
121 d 13 h 15 m |
|
Single- and Three-Phase
Power Mode |
| Average Time |
Logging Time (1 area) |
| 1 sec |
1 h 40 m |
| 2 sec |
3 h 21 m |
| 5 sec |
8 h 22 m |
| 10 sec |
16 h 45 m |
| 30 sec |
2 d 2 h 17 m |
| 1 min |
4 d 4 h 35 m |
| 5 min |
20 d 22 h 55 m |
| 10 min |
41 d 21 h 50 m |
| 15 min |
62 d 20 h 45 m |
| |
|
| |
Logging Time (3 areas) |
| 1 sec |
4 h 47 m |
| 2 sec |
9 h 34 m |
| 5 sec |
23 h 57 m |
| 10 sec |
1 d 23 h 54 m |
| 30 sec |
5 d 23 h 25 m |
| 1 min |
11 d 23 h 25 m |
| 5 min |
59 d 21h 5 m |
| 10 min |
119 d 18 h 10 m |
| 15 min |
179 d 15 h 15 m |
|
|