Fluke Norma 4000/5000 Series
High Precision Power Analyzer -
Functions - Measured Values -
Power Phases |
|
|
|
| |
 |
| |
|
Fast
Fourier Transformation (FFT) |
|
Calculations of harmonics with graphical representation.
Up to 3 bar graphs are displayed at the same time. |
|
Measured
values: U, I, P per phase |
|
Order:
1st to 40th harmonics, maximum half sample frequency |
|
|
Digital
Oscilloscope (DSO) |
Simultaneous
display of up to 3 measured values on sample level. Quick view
of curve form and distortion. |
|
Integration
Function (energy) |
Simultaneous
display of up to 6 configurable numeric values. Start/Stop
conditions and positive negative direction available. |
|
Vector
Display |
Vector display
of HO1 up to 6 signals. For easy testing of the right connection
of the instrument and quick overview of the phase angle of each
signal. |
|
Recorder |
Display of
average values over time for trend determination. |
|
RAM Data
Memory |
Storing of
sample and average values; setting of start and stop conditions.
From the RAM approximately 4MB are available for the storage of
measured values. |
|
Configuration |
Set up the
analyzer to measure and display data in the format required. |
|
| |
| |
 |
| |
|
Measured Values |
Non-gapping calculation of averaged
values for each phase. In three phase system additionally
calculation of total power and averaging of Voltage and Current
of the three phases. The fundamental H01 will be calculated in
synchronous mode also for these values below. |
|
Urms effective value, U rm rectified
mean, Um Mean value |
|
Up-, Up+, Upp peak values |
|
Ucf crest factor, Ucf, Uff form
factor |
|
Ufc fundamental content |
|
Uthd distortion factor DIN, IEC |
|
Irms effective value, Irm rectified
mean, Im mean value |
|
Ip, Ip+, Ipp peak values |
|
Icf crest factor Icf, form factor |
|
Ifc fundamental content |
|
Ithd distortion factor DIN, IEC |
|
P active power (W) |
|
Q reactive power (Var) |
|
S apparent power (VA) |
|
ё, cos. phase angular |
|
Integral function for active power
P, reactive power Q, apparent power S, voltage (Um) and current
(Im) |
|
Number of digits 4 or 5 dependent on
measured value. |
|
| |
| |
 |
| |
| The Fluke Norma 4000 Power Analyzer
can be equipped with up to three power phases and the Fluke
Norma Power Analyzer can be equipped with up to six power
phases. Users can select the power phase best suited for their
application. Specifications vary depending on the model of the
power phase. Each modular plug-in
power phase consists of a voltage and a current measurement
channel. Each measuring channel is available for each basic
unit, however only one kind of channel can be used per unit.
Check standard configurations. |
|
| |
 |
 |
| Fluke Norma 4000
(rear panel) |
Fluke Norma 5000
(rear panel) |
|
| |
| Modular plug-in Power Phase
Overview |
| |
|
Channel |
Accuracy |
Current Range |
Sampling Rate |
Bandwidth |
| PP42 |
0.2% (0.1% of rdg +
0.1% of rdg |
20A |
341kHz |
3MHz |
| PP50 |
0.1% (0.05% of rdg +
0.05% of rdg |
10A |
1MHz |
10MHz |
| PP54 |
0.1% (0.05% of rdg +
0.05% of rdg |
10A |
341kHz |
3MHz |
| PP64 |
0.03% (0.02% of rdg +
0.01% of rdg |
10A |
341kHz |
3MHz |
|
| |
|