AQ1100 (MFT-OLTS) Optical Loss Test Set
 

Overview
The AQ1100 is an optical loss test set combining an optical power meter and a light sources in one unit. An optical power meter is a measuring instrument usually used for optical loss tests. The AQ1100 supports up to MM850/1300nm and SM1310/1550/1625nm. Also, you can select a +27dBm high power optical meter. For the light source, three models are available depending on the wavelength and fiber used. For the optical power meter, you can select from three models depending on the measurement power and purpose of the optical power meter.
 

AQ1100 (MFT-OLTS) Optical Loss Test Set

Features
  • 5.7 inch color LCD for easy viewing.
  • Multi-Language support.
  • Multi-core fiber measurement with a pair set.
  • USB port for data storage.
  • PING Test function (optional).
  • Visible Light Source (optional).
    SM1310/1550nm
    SM1310/1550/1625nm
    MM850/1330nm and SM1310/1550nm.
  • Standard Accessories supplied with instrument: Power cord, AC adapter, battery pack, hand belt, user's manual (CD-ROM), and operation guide.

AQ1100 Datasheet (PDF)
(documents are in PDF format and will open in a new window)

AQ1100 Front View above - AQ1100 Top View below

AQ1100 (MFT-OLTS) Optical Loss Test Set  (Top View)

Specifications by Model (23°C ± 2°C unless otherwise noted)

Light Source Performance

Model AQ1100A Model AQ1100B Model AQ1100D

Wavelength (nm)Note1

1310/1550 ±25 1310/1550/1625 ±25 1310/1550 ±25 (SM)
850/1300 ±30 (GI)

Light Emitting Device

LD LD LD (SM), LED (GI)

SM (LD) Spectral Width Notes 1,2

<5nm / <10nm <5nm / <10nm / <10nm <5nm / <10nm

GI (LED) Spectral Width Notes 1,3
(FWHM)

- - 40nm (typ.) / 140nm (typ.)

Optical Output Level

-3 dBm ±1 -3 dBm ±1 SM: -3 dBm ±1
GI: -20dBm ±1

Level Stability Note 4

±0.05 dB ±0.05 dB SM: ±0.05 dB
GI: ±0.1 dB

Modulation Mode

CW, CHOP (270Hz, 1kHz, 2kHz) Note 5

Applicable Fiber

SM (ITU-T G.652) SM (ITU-T G.652) SM (ITU-T G.652)
GI (50/125µm)

Optical Connector

SC, FC, 1.25mm ferrule, AC/Angled-PC SC, FC, 1.25mm ferrule

Laser Class

1 1 1
       

Optical Power Meter Performance and Functions

Function

Standard (/SPM) High Power (/HMP) Model PON (/PPM)

Wavelength Setting

Simple mode: 850/1300/1310/1490/1550/1625/1650nm
Detail mode setting: 850nm to 1650nm, 1nm step
CWDM mode setting: 1270nm to 1610nm, 20nm step
1310/1490/1550nm
(1490nm and 1550nm can be measured separately)

Power Range

-70 to + 10 (CW)
-70 to + 7 (CHOP)
-50 to + 27 (CW)
-50 to + 24 (CHOP) Note6
-70 to +10: 1310/1490nm
-50 to +27: 1550nm

Noise Level

0.5nW
(-63dBm, 1310nm)
50nW
(-43dBm, 1310nm)
0.5nW (-63dBm, 1310nm)
50nW (-43dBm, 1550nm)

Uncertainty Under Standard Conditions Note7

±5% ±5% ±5dB (10%)

Readout Resolution

0.01 0.01 0.01

Level Unit

Absolute: dBm, mW, µW, nW; Relative: dB

Modulation Mode

CW
CHOP (270/1kHz/2kHz)
CW
CHOP (270/1kHz/2kHz)
CW

Average Function

1, 10, 50, and 100 times

Logging Function

Measurement Intervals: 500ms, 1s, 2s, 5s, 10s
Measurement Count: 10 to 1000

Note1:

23°C ± 2°C CW

Note2:

RMS (2σ, -20dB)

Note3:

Envelope (-3dB)

Note4:

for 15 minutes at a constant temperature within 23°C ± 2°C

Note5:

CW and 270Hz only at 850nm

Note6:

Except for 850nm and 1650nm

Note7:

23°C ± 2°C, standard conditions (CW, 1310nm, 100µW, SMF), at 1550nm/PPM

Note8:

LD ON (in screen save mode)
   

General Specifications

Display

5.7 inch color LCD (640 x 480)

Loss Mode

Auto loss test, Loopback test, Multi-core test (only with /SPM or /HPM)

Internal Memory

128 MByte

External Interface

USB 1.1 Type A and Type B (mini) one each

Operating Temperature

0°C to 45°C (0° to 35°C when charging the battery)
Humidity 85% RH or less non-condensation

Storage Temperature

-20°C to 60°C
Humidity 85% RH or less non-condensation

Safety Standard

EN 61010-1, EN 60825-1 (laser safety)

EMC

EN 61326-1 Class A, EN 55011 Class A Group 1, C-Tick EN 55011 Class A Group 1.

Power Supply (AC adapter)

100 Volts to 120 Volts AC, 200 Volts to 240 Volts AC, 50/60Hz

Power Supply (Internal Battery)

Li-ion, duration 6 hoursNote8, charging time 5 hours

Battery Life Note6

approx 40 hours (as measured using alkaline dry cells. at 25°C with CW light input)

Dimensions

217.5mm (W) x 157mm (H) x 74mm (D) (excluding projections)

Weight

approx. 1kg (including internal battery)

Included Accessories

Two alkaline dry cells, neck strap, carrying pouch, and user's manual

 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Tuesday, 15 November 2011