Overview
The AQ1200 is a multifunctional hand-held OTDR that
combines all the necessary field test functions in one
unit. It offers various functions, including an OTDR
function that features short 80cm event dead zone, a
fault locator function that is effective in locating a
fault, an optional loss test function that combines
light sources and an optical power meter in one unit. A
visible light source is also available as an option,
also the instrument allows the connection of a fiber
end-face inspection probe.
|
|
|
 |
Features
- OTDR that supports
SM1310/1550nm with a short 80cm event dead zone.
- Quick power UP for faster
operations.
- Able to display trace and
event information at the same time.
- Full auto mode for novice
users and information tips for more experienced
users.
- Bright LCD screen for easy
viewing inside buildings and outside as well.
- Includes Fault Locator
functions for fast measurements.
- Supports external USB
Video fiber inspection probe.
- Standard Accessories
supplied with instrument: Power cord, AC adapter,
battery pack, hand belt, user's manual (CD-ROM), and
operation guide.
AQ1200 Datasheet
(PDF)
(documents
are in PDF format and will open in a new window) |
|
| AQ1200 Front View above
- AQ1200 Top View below |
|
 |
| |
|
Specifications per
Model (23°C ± 2°C unless
otherwise noted) |
|
Item |
Model AQ1200A |
Model AQ1200BNote1 |
Model AQ1200CNote1 |
|
Wavelength (nm) |
1310/1550
±20nm Note2 |
1625
±10nm |
1650
±5nm
Note 3
1650nm ±10nm Note 4 |
|
Applicable Fiber |
SM (ITU-T G.652) |
|
Distance Range |
0.5, 1, 2, 5, 10, 20,
50, 100, 200 km |
|
Pulse Width |
3ns, 10ns, 20ns, 50ns,
100ns, 200ns, 500ns, 1µs,
2µs, 5µs, 10µs |
|
Dynamic Range
Note5 |
34/32dB Note6 |
33dB Note7 |
34dB Note7
GI: -20dBm ±1 |
|
Event Dead Zone
Note 8 |
0.75M Note 9 |
|
Annotation Dead Zone
Note 10 |
4m/5m |
7m |
7m |
|
Optical Power Control |
- |
Normal/Low |
Normal/Low |
|
|
|
|
Note1: |
Pulse light output power at
1625nm and 1650nm, + 15dBm or
less, built-in 1310 and 1550nm
cut filter. |
|
Note2: |
±25nm is guaranteed. |
|
Note3: |
At a point -20dB from the pulse
light output peak value
(measured after 30 minutes or
more from power-on at an ambient
temperature of 23°C). |
|
Note4: |
At a point -60dB from the pulse
light output peak value
(measured after 30 minutes or
more from power-on at an ambient
temperature of 23°C). |
|
Note5: |
SNR: 1, pulse
width: 10µs,
measurement time: 3 minutes.
When angled-PC connectors are
used, each dynamic range
decreases by 0.5db. |
|
Note6: |
32/30 dB is guaranteed. |
|
Note7: |
30dB is guaranteed. |
|
Note8: |
Pulse width: 3ns, return loss:
55dB or more. |
|
Note9: |
0.8m is guaranteed. |
|
Note10: |
Pulse width:
10ns, return loss: 55dB or more,
at a point where the backscatter
level is within
±0.5dB of the normal value. |
|
|
|
|
Specifications per Option (Light
source & Optical powermeter
option) |
|
|
Optical Power Meter
|
|
Function |
Standard (/SLT) |
High Power (/HLT) |
Model PON (/PPM) |
|
Wavelength Setting |
850/1300/1310/1490/1550/1625/1650nm
or 800 to 1700nm (in 1nm steps)
or CWDM wavelength (1270 to 1610nm, 20nm
steps) |
1310/1490/1550nm |
|
Power Range (CW) |
+ 10 to -70 dBm |
+ 27 to -50 dBm
Note3 |
+ 10 to -70 dBm
Note1
+ 27 to -50 dBm Note2 |
|
Power Range (CHOP) |
+ 7 to -60 dBm |
+ 24 to -50 dBm
Note3 |
--- |
|
Noise Level |
0.5nW (-63dBm, 1310nm) |
50nW (-43dBm, 1310nm) |
0.5nW (-63dBm, 1310nm)
50mW (-43dBm, 1550nm) |
|
Uncertainty Under
Standard Conditions Note4 |
±5% |
±5% |
±0.5dB |
|
Readout Resolution |
0.1 |
0.1 |
0.1 |
|
Level Unit |
Absolute: dBm,
mW, µW, nW.
Relative: dB |
|
Modulation Mode |
CW, CHOP, (270Hz,
1kHz, 2kHz) |
|
Average Function |
1, 10, 50, and 100
times |
|
|
|
|
|
|
Light Source |
|
|
|
|
Wavelength (nm) |
1310/1550
±25nm (AQ1200A), 1625
±10nm (AQ1200B),
1650 ±5nm Note5,
1650 ±10nm Note6
(AQ1200C) |
|
Optical Output Level
(dBm) |
-3
±1 |
-3
±1 |
-3
±1 |
|
Level Stability (dB)
Note7 |
±0.05
(AQ1200A), ±0.15 (AQ1200B, AQ1200C) |
|
Modulation Mode |
CW, 270Hz, 1kHz, 2kHz |
|
Application Fiber |
SM (ITU-T G.652) |
|
|
|
|
|
|
Memory and Logging
Function |
Measurement data
storage: 10 to 1000 data
Logging Interval: 0.5, 1, 2, 5, or 10
seconds |
|
Auto Loss Test
Function |
Loss measurement with
light source and optical
powermeter interlock |
--- |
|
|
Note1: |
at
1310/1490nm |
|
Note2: |
at
1550nm |
|
Note3: |
at
1300 to 1600nm |
|
Note4: |
Power level: 100µW
(-10dBm); CW, Wavelength: 1310 ±29nm (1550nm
±10nm for 1550 nm setting of /PPM),
Spectral width: 10nm or less (1310nm),
ambient temperature: 23°C ±2°C,
Optical fiber: SM (ITU-T G.652), Optical
connector: FC/PC, Wavelength setting error:
0.5nm or less,
excluding aging (add 1% one year after
calibration) |
|
Note5: |
At a point -20dB from the
pulse light output peak value (measured
after 30 minutes or more from
power-on
ambient
temperature: 23°C) |
|
Note6: |
At a point -60dB from the
pulse light output peak value (measured
after 30 minutes or more from
power-on
ambient
temperature: 23°C) |
|
Note7: |
Constant temperature within
23°C
±2°C (for 15 minutes) |
|
| |
|
|
Visible Light
Source (VLS) |
|
|
Optical Connector |
2.5mm ferrule type |
 |
|
Center Waveform |
650nm
±20nm |
|
Optical Output Level |
-3dBm or more (peak) |
|
Modulation Mode |
CHOP approx. 2Hz |
|
Laser Class |
3R |
|
| |
| |
|
General
Specifications |
|
Display |
5.7 inch color LCD (640 x
480) |
|
Interface |
USB 1.1 Type A and Type B
one each |
|
Operating Temperature |
0°C
to 45°C (0° to 40°C using AC adapter) (0° to
35°C when charging battery)
Humidity 20% to 85% RH non-condensation |
|
Storage Temperature |
-20°C
to 60°C
Humidity 85% RH non-condensation |
|
Safety Standard |
EN 61010-1, Laser: Class
1M (EN 60825-1) 21CFR1040.10 |
|
EMC |
EN 61326-1 Class A, EN
55011 Class A Group 1 |
|
Power Supply (AC adapter) |
100 Volts to 240 Volts AC,
50/60Hz |
|
Power Supply (Internal
Battery) |
Run time: 6 hours;
Recharge time: 5 hours |
|
Dimensions |
217.5mm (W) x 157mm (H) x
74mm (D) (excluding projections) |
|
Weight |
approx. 1kg (including
protector and battery pack) |
|
Included Accessories |
AC adapter, battery pack,
hand belt, user's manual (CD-ROM), and operation
guide |
|
|
|