Standard and High-Performance Models |
|
There are two models available, Standard and
High Performance. The High performance model
provides even higher wavelength accuracy and
dynamic range.
High Wavelength Accuracy
±0.01nm
|
|
|
Wavelength Range |
AQ6370C-10 |
AQ6370C-20 |
|
1520 nm to 1580 nm |
±0.02 nm |
±0.01nm |
|
1580 nm to 1620 nm |
±0.02 nm |
±0.02 nm |
|
1450 nm to 1520 nm |
±0.04 nm |
±0.04 nm |
|
Full Range |
±0.1 nm |
±0.1 nm |
|
|
Ultra-High Dynamic Range
78dB typ. |
|
With the reduced
stray-light in the monochromator, the AQ6370C
achieves a typical ultra-high dynamic range of
78dB. |
|
|
Unit |
AQ6370C-10 |
AQ6370C-20 |
|
Peak
±1.0 nm |
73dB |
73dB (typ. 78dB) |
|
Peak
±0.04 nm |
62dB |
64dB (typ. 70dB) |
|
Peak
±0.2 nm |
45dB |
50dB (typ. 55dB) |
|
Resolution
setting 0.05 nm |
|
| |
|
| Example of the dynamic
range |
Example of the spectral
shape |
 |
| |
|
|
Sharper Filter Edge |
|
The high performance model can also achieve a
higher dynamic range within 0.2nm of the peak
wavelength. With the sharper spectral
characteristics of the monochromator, spectral
signals in close proximity can be separated
clearly and measured accurately. |
|
|
Unit |
AQ6370C-10 |
AQ6370C-20 |
|
Peak
±0.2 nm |
55dB |
58dB (typ. 60dB) |
|
Peak
±0.1 nm |
37dB |
45dB (typ. 50dB) |
|
Resolution setting
0.02 nm |
|
| |
|
|
Stray-Light suppression ratio 80dB |
Example of the stray-light suppression ratio |
|
This new specification provides stray-light suppression when
high dynamic mode, usually taking longer measurement time,
is not used. The AQ6370 contributes to shortening the
measurement time with the high stray light suppression
ratio.
|
AQ6370C-10 |
AQ6370C-20 |
|
73dB |
76dB (typ.
80dB) |
|
Resolution setting 0.1 nm |
|
|
 |
| |
|
|
Wide Level Range
+20dBm to -90dBm |
|
The AQ6370C can
measure high power sources such as optical amplifiers and
pump lasers for Raman amplifiers, and very weak optical
signals as well. Measurement sensitivity can be chosen from
seven categories according to test applications and
measurement requirements.
-
Improved
level sensitivity: -85dBm (1000 nm to 1300 nm).
-
Smoothing
Function - Reduce noise on measured spectrum.
-
High dynamic
mode - Obtain a better dynamic range by reducing the
influence of stray-light, which is caused when the input
is a strong optical signal.
|
|
Free Space Input |
- Multimode and single mode fiber on
the same OSA.
AQ6370's low insertion loss for multimode
fiber is also beneficial to maintain the
excellent measurement efficiency.
- Small insertion loss variation at the
input
connector increases measurement
repeatability.
- No damage connecting fibers
because there is no physical contact.
- APC level correction
The APC level correction function corrects
the level offset caused by an insertion loss
of angled PC connector.
|
 |
|
|
Excellent Efficiency |
|
Fast Sweep:
0.2sec/100nm
With an advanced monochromator, faster electrical circuits,
and noise reduction techniques, the AQ6370C achieves fast
measurement speed even when measuring a steep spectrum from
DFB-LD or DWDM signals, or when measuring a low power signal
from a broadband light source.
|
 |
OSNR Measurement on
DWDM System
DWDM channels allocated at 50GHz spacing
can be measured and analyzed |
Optical
Amplifier (EDFA) Measurement |
| |
|
|
WDM OSNR Test |
|
AQ6370C's wide
close-in dynamic range allows accurate OSNR measurement of
DWDM transmission systems. The built-in WDM analysis
function analyses the measured waveform and shows peak
wavelength, peak level and OSNR of WDM signals up to 1024
channels simultaneously. The curve fit function is used to
accurately measure noise levels.
|

Example of analysed data table
|
|
Wide Span Sweep yet High
Resolution |
|
The 50,001 data
sampling points expands measurement range in a single sweep
while keeping a high wavelength resolution. This makes your
measurement easier and more efficient than conventional
systems. |
| |
|
Easy Operation |
|
Trace Zooming
-
Change display
conditions, such as center wavelength and span, by
clicking and dragging the mouse.
-
Enlarge your
area of interest instantly and move it at will.
Mouse and
Keyboard Operation
-
Front panel
operation proven intuitive and easy to use by our many
users.
-
Even easier
with a mouse.
-
The keyboard
helps enter labels and file names.
|
|
Easy Data
Handling |
- USB Storage
USB interfaces support large-capacity
removable memory and hard disk drives.
- 512MB Internal Memory
for over 20,000 traces.
- All-at-Once Trace Filing
All seven traces can be saved in one file at
once.
|
 |
|