Leda Electronics Logo. Western  Australia's largest distributor of Test Instruments Leda Electronics Showing The Way

 
Portable and Hand-Held Instruments > Model CL155
Yokogawa Test and Measurement Logo

Portable and Hand-Held Instruments Including: ● Calibrators ● DMMs ● Clamp-On Testers ● Portable Data Loggers ● Insulation Testers ● Thermometers ● Portable Analog Meters ● Light Meters, and ● Precision Measuring Equipment.

Model CL155
Clamp-On Tester for AC Current Measurements

Yokogawa Model CL155 Clamp Meter for AC Current Measurement

Yokogawa CL155 Features
 
bullet AC current measurement with current ranges up to 2000A.
bullet True RMS display.
bullet AC/DC voltage and resistance measurements.
bullet 54mm in diameter of measurable conductor.
bullet DC output function.
bullet Data hold function.
bullet Sleep function
bullet Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032  (CAT III 600V). (CAT II 1000V).
 
 
Yokogawa Model CL155 Specifications
 

Parameter

Reference

Accuracy

AC Current

400A

1.0+3 (50 to 60Hz)

400A

2.0+3 (40 to 1kHz)

2000A (0 to 1500A)

1.0+3 (50 to 60Hz)

2000A (0 to 1500A)

3.0+3 (40 to 1kHz)

2000A (1500A to 2000A)

3.0 (50 to 60Hz)

AC Voltage

40/400/750V

1.0+2 (50 to 60Hz)

40/400/750V

1.5+3 (40 to 1kHz)

DC Voltage

40/400/1000V

1.0+2

Resistance
 

400Ω/4kΩ/40kΩ/400kΩ
 

1.5+2 Beeps at below 50Ω ±35Ω (continuity check)

DC Output
 

400A (0 to 400mV)

±1.5% rdg ±0.5mV (50 to 60Hz)

400A (0 to 400mV)

±2.5% rdg ±0.5mV (40 to 1kHz)

2000A (0 to 150mV/0 to1500A)

±1.5% rdg ±0.5mV (50 to 60Hz)

2000A (0 to 150mV/0 to1500A)

±3.5% rdg ±0.5mV (40 to 1kHz)

2000A (150mV to 200mV/
1500A to 2000A)

±3.5% rdg (50 to 60Hz)

 
At 23°C ±5°C, 75% RH or less
Accuracy: ±(% rdg + dgt) = ±(% readout + value of least significant digit)
 
 
Yokogawa Model CL155 General Specifications
 

Parameter

Specification

Method of detection

Mean Value

Display

LCD (Digital Display: 3999 counts)

Response Time

Approx 2 seconds

Range Switching

Manual on AC current range.
Auto range on AC/DC voltage and Resistance ranges.

Data Hold

On all ranges

Peak Hold

On AC Current range

Ambient Temperature

0°C to 40°C

Relative Humidity

up to 40°C     RH 85%   (no condensation)

Influence of External Magnetic Field

1A or less at 400A/m

Influence of Conductor Position

±(2.0% rdg + 3dgt) or less

Safety Standard

EN61010-1, EN61010-2-031, EN61010-2-032

Circuit Voltage

1000Vrms or less

Withstanding Voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3) x 2 or LR6 x 2

Battery Life

Approx. 150 hours (continuous)

Consumed Current

Approx 5mA

Sleep Function

Approx. 10 minutes after last switch operation.

Diameter of Measurable Conductor

54mm at maximum

Dimensions

105mm (W) x 247mm (H) x 49mm (D)

Weight

Approx. 470g

Accessories

User's manual (IM CL150), batteries, Carrying case (93034)

 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au