Overview
The CW10 is more like a tester type rather than a
recorder, which can measure single phase AC and DC
Power, Voltage, Currents, Power Factor, Frequency, and
Harmonics. It will also contribute to workers
maintenance of not only consumer equipment but equipment
for renewable energy such as solar and wind power
generation.
|
|
|

CW10 Datasheet (PDF)
(documents
are in PDF format and will open in a new window)
|
Features and Benefits
- AC/DC Power up to 600kW,
AC/DC Voltage to 1000V, AC/DC Current to 600 Amps.
- True RMS for AC
measurements.
- Harmonics 1st up to 25th
order.
- Power fluctuation using
the ACA Inrush and Peak Hold functions.
- Frequency, Resistance,
Continuity, Diode Check, and Power Factor
measurements.
- Display reading up to 9999
counts.
- Jaw opening 45mm max.
(measurable conductor diameter 37mm).
- CAT IV 600V and CAT III
1000V compliant for safety.
- Backlight on the display
area turns on and a white LED automatically
illuminates the front of jaw when clamping.
- Non-contact Voltage
detection (Red LED lights uo on detection).
- Easy Operation with the
navigation key.
- Low Pass Filter, Phase
Detection, AC/DC Auto Sense.
Instrument Supplied With:
- Test lead set (red and
black).
- 9 volt alkaline battery
(6LR61).
- Carrying case.
- User's Manual.
|
|
|
General
Specifications |
|
Display Count |
9999 /6000 |
|
Measuring Rate |
3 times/second |
|
Over Range Indicator |
"OL" or ("-OL") |
|
Auto Power Off |
approx. 15 minutes |
|
Low Battery Indicator |
Yes (four steps) |
|
Power Supply |
1 x 9 Volt type 6LR61
Alkaline battery. |
|
Battery Life |
approx. 20 hours
(using alkaline battery, with backlight off) |
|
|
|
|
Operating Temperature |
0°C
to 50°C (with no condensation) |
|
Relative Humidity |
≤ 80%
RH (0°C to 30°C) |
|
≤ 75%
RH (30°C to 40°C) |
|
≤ 45%
RH (40°C to 50°C) |
|
Storage Temperature |
-10°C
to 50°C, 80% RH or less (with battery
removed) |
|
Temperature
Coefficient |
at 0°C
to 18°C and 28°C to 50°C
add 23 ± 5°C accuracy x 0.2/°C |
|
|
|
|
Withstand Voltage |
AC 6800V rms 5 sec.
(between the core and the base)
AC 4300V rms 5 sec. (between the core and
the voltage input terminals)
AC 6800V rms 5 sec. (between the voltage
input terminals and the case) |
|
Insulation Resistance |
100MΩ
or greater at 1000V DC
(between the core and the case, the core and
the voltage input terminals and the voltage
input terminals and the case) |
|
|
|
|
Safety Standards |
EN 61010-1, EN
61010-2-032
1000V CAT III, 600V CAT IV |
|
Test Leads |
EN 61010-031
|
|
Pollution Degree |
2 (indoor use) |
|
EMC Standards |
EN 61326-1,
EN61326-2-1, EN 61326-2-2, EN 55011 |
|
|
|
|
Dimensions |
242mm (L) x 87.5mm (W)
x 51mm (D) |
|
Weight |
approx. 435g
(including battery) |
|
|
|