Features
- High accuracy:
±0.01%, with a maximum
allowable input of 500kPa (130kPa range model).
-
Measurement with DC Volts and DC Amps.
-
24 Volt DC output.
-
Percentage reading.
-
Error reading.
-
Measurement data memory.
-
D/A conversion output, comparator output, and
external trigger input (Optional).
-
GP-IB or RS-232 interfaces.
-
12 Volt DC power supply.
-
Battery operation (optional).
-
Std. Accessories: Connector for DC power supply,
two rubber pads for rear foot, labels for
indicating measurement object, one test lead,
power cord and user's manual.
MT220 Series Datasheet (PDF)
(documents
are in PDF format and will open in a new window) |
| |
|
High-Performance, and High-Efficiency Field
Calibration |
|
In electric power, gas,
nuclear power, oil refineries, petrochemical and
pharmaceutical plants, numerous sensors are used to
measure such variables as pressure, temperature and
flow rate, and to automate the process. These
sensors must be calibrated periodically to maintain
product quality. However, because there are
typically so many pressure and differential pressure
transmitters out in the field, the transmitters are
usually calibrated in-situ. This calibration
accounts for much of plant maintenance work.
Efficiency is therefore crucial to maintain uptime
of equipment and facilities.
The MY220 is a precision
digital manometer for use with pressure/differential
pressure transmitters and is designed to maximize
the efficiency of field calibration work.
|
|
High Allowable Input Pressure |
|
The maximum allowable input
pressure is as high as 500kPa (such as in the 130kPa
range model). Now you don't have to worry about
sensor breakdown due to overrange pressure input.
|
|
Functions Tailored to Your Calibration Work |
|
Calibration involves inputting
the same pressure level to both a calibrator and a
transmitter and comparing the transmitter output
with a value measured by the calibrator. The MT220
comes with all the functions you need for such
calibration work in the plant or field. Practical
functions include measuring transmitter output (1 to
5V or 4 to 20mA), outputting 24 Volts DC for driving
the transmitter, and indicating the transmitter
output error as a percentage value. The MT220 even
has a pressure range pre-adjusted to that of
transmitters.
|
|
Full Support for Higher Accuracy of Pressure, and
Differential Pressure Transmitters |
|
The accuracy of pressure/differential pressure
transmitters has continued to improve, from
±0.25% to ±0.1%, and now to
±0.075%. That means the accuracy and stability of
the manometers used to calibrate these transmitters
must keep pace.
The MT220
employs Yokogawa's original silicon resonant sensor,
a high precision pressure sensing device. They have
also set up an advanced calibration environment,
including a tightly-controlled traceability system.
As a result, their calibrators feature a basic
accuracy as high as ±0.02%, and excellent stability.
With the MT220, you can verify the performance of
even the most accurate of pressure/differential
pressure transmitters, i.e. ±0.075%. |
| |
|
Automation of Pressure Measurement |
|
D/A Conversion Output (Optional)
Outputs a D/A converted signal
through the external terminal. This
feature lets you easily send measurement
data to a measuring system or a
recorder.
Comparator
Output and Trigger Input (Optional)
The comparator output provides the
result of comparing an input level with
preset upper and lower limits through
the external terminal. You can also
apply a start-of-measurement trigger
using the rising edge of an external
trigger signal supplied through the
external trigger input. These features
help automate your production/inspection
lines of pressure-related products.
GP-IB (or
RS-232) Interface - Choose when ordering
This feature lets you read measured
values into your PC or set measurement
conditions from the PC. Communication is
still possible even when the instrument
is operating on batteries or the DC
power source. |
 |
|
| |
| |
|
Yokogawa Traceability
System for Ensuring Top Reliability of Pressure
measurement by customers |
|
The company is committed to controlling and
maintaining the accuracy of standards installed in
the Standards Room of its Kofu plant.
|
|
 |
|
Front Panel |
|

|
- Pressure unit
selector key
Used to select from up to seven units; factory
set to kPa. (The units other than kPa are
extralegal measurement units prescribed by the
Measurement Law).
- LCD for 5.5-digit
readings (pressure measurement) and 4.5-digit
readings (measurement with DCV and DCA
functions); 4.5-digit and 3.5-digit readings,
respectively, for MT220 Model 767305.
The EL-backlight LCD presents a clear, sharp
view even in dark places.
- Relative key
Shows the deviation from a specified pressure
measurement.
- Zero calibration key
Adjusts the zero reading to the atmospheric
pressure or vacuum.
- DCV/DCA function
keys
Turn on or off the DCV/DCA functions, or toggle
between the functions.
- 24V DC output
ON/OFF key and terminals
Used as a power supply for operating a
transmitter during field calibration work.
- Percent input
readout keys
▫ Pressure: Can be
displayed as a percentage with reference to your
desired full scale set point. In addition you
can define selected pressure readings as the
upper and lower limits of a full scale.
▫ Volt and ampere DC: Can be displayed as a
percentage by defining the 1 - 5V or 4 - 20mA
range as the
0 - 100% range.
-
Error readout key (% ERROR function)
Shows an error in the volt-DC or ampere-DC
reading of a pressure measurement (transmitter
output) as a percentage value.
-
Readout digits selector key
Turns off LSD of a pressure reading from the
display to avoid difficulty in reading the value
due to fluctuations in the LSD.
-
Parameter setting key
Sets the measurement conditions, communication
interface, etc.
-
Data storage keys
Up to 2,000 data items can be stored in the
internal memory.
-
Pressure input connection
You can choose from three choices of connector
configuration. The same connection is found on
the rear panel.
-
DCV/DCA measurement terminals
Greatly help reduce the field calibration work
required for pressure/differential pressure
transmitters. The current (A) terminal is
protected by a built-in fuse against overrange
input levels.
|
|
Rear Panel |
|

|
| |
|
Silicon-Resonant Sensor |
|

|
Overall structural view of the Yokogawa
original silicon resonant sensor*, a major factor in
the high performance of the MT210/MT210F series.
Note*: Technology that has won the Ohkochi Grand
Technology Prize and the Chairman's Award of the
Japan Federation of Economic Organizations
(Keidanren). |
| |
|
Major users of YOKOGAWA digital manometers |
|
National standards
institutions in Japan and abroad; institutions
related to nuclear power generation; national and
public research institutions; electric-power
companies; automakers and their affiliates; electric
appliance manufacturers; precision instrument
manufacturers; semiconductor and electronic
component mfg's; pharmaceutical mfg's; Heavy
electrical machinery builders; oil refinery and
petrochemical companies. |