Leda Electronics Logo. Western  Australia's largest distributor of Test Instruments Leda Electronics Showing The Way

 
Yokogawa Test and Measurement Logo

Yokogawa 4 to 30 Channel Data Loggers

MVAdvanced, MV1000 and MV2000 Paperless Recorder
Ordering Information

Yokogawa Ordering Information for MV1000 and MV2000 Series of Paperless Recorders
 
 
MV1000 Model, Suffix and Option Codes

Model Code
 

Suffix Code

Optional Code

Description
 

MV1004

 

 

4

channel 

125ms

Fast sampling mode:

25ms

MV1006

 

 

6

channel 

1s

Fast sampling mode:

125ms

MV1008 Note 9

 

 

8

channel 

125ms

Fast sampling mode:

25ms

MV1012

 

 

12

channel

1s

Fast sampling mode:

125ms

MV1024 Note 9

 

 

24

channel

1s

Fast sampling mode:

125ms

Internal Memory

-1

 

Standard Memory 80 MB

-2

Large Memory 200 MB

External Media

-4

CF Card (with Media) + USB

Language

-2

English/German/French

-4

Korean

Input Terminal

-1

Clamped Terminal

-2

Screw Terminal (M4)

Power Supply

-1

100V AC, 240V AC

-2

12V DC Note 1

-3

Rechargeable Battery Note 1

Power Cord

D

Power Cord UL/CSA Standard

F

Power Cord VDE Standard

R

Power Cord SAA Standard

Q

Power Cord BS/PSB Standard Note 11

H

Power Cord GB Standard

P

Power Cord EK Standard Note 10

W

Power Cord without AC Adapter Note 2

Options

 

/A1

Alarm Output 2 points Note 3 and Note 9

/A2

Alarm Output 4 points Note 3 and Note 9

/A3

Alarm Output 6 points Note 3  Note 4 and Note 9

/C2

RS-232 Interface Note 5

/C3

RS-422/485 interface Note 5

/F1

Fail/Status Output Note 4 and Note 9

/M1

Mathematical Functions

/N1

Cu10, Cu25 RTD input/3 leg isolated RTD

/N2

3 leg isolated RTD Note 6

/N3

Extended Input Type (PR40-20, Pt50, etc.)

/R1

Remote Control

/TPS2

24V DC Transmitter Power Supply (2 loops) Note 7 and Note 8

/PM1

Pulse Input Note 8 and Note 9

(including remote control and Maths function)

/CC1

Calibration Correction Function

 
Note 1: An AC adapter is included as a standard accessory.
Note 2: 'W' can be specified for only 12V DC.
Note 3: /A1, /A2 and /A3 cannot be specified together.
Note 4: /A3 and /F1 cannot be specified together.
Note 5: /C2 and /C3 cannot be specified together.
Note 6: /N2 can be supplied for only MV1006, MV1012 and MV1024.
Note 7: In case that /TPS2 is specified, /A2, /A3, /F1 and /PM1 cannot be specified together.
Note 8: In case that /PM1 is specified, /A3, /M1, /R1, and /TPS2 cannot be specified together.
  And combination of /A2/F1 cannot be specified together.
Note 9: In case that MV1008, MV1024 is specified, /A1, /A2, /A3, /F1, /R1, /TPS2 and /PM1 cannot
  be specified together.
Note 10: In case that 100V AC, 240V AC is specified, 'P' cannot be specified together.
Note 11: BS standard is specified only 100V AC, 240V AC.
 
 
 
MV2000 Model, Suffix and Option Codes

Model Code
 

Suffix Code

Optional Code

Description
 

MV2008

 

 

8

channel 

125ms

Fast sampling mode:

25ms

MV2010

 

 

10

channel 

1s

Fast sampling mode:

125ms

MV2020

 

 

20

channel 

1s

Fast sampling mode:

125ms

MV2030

 

 

30

channel

1s

Fast sampling mode:

125ms

MV2040

 

 

40

channel

1s

Fast sampling mode:

125ms

MV2048

 

 

48

channel

1s

Fast sampling mode:

125ms

Internal Memory

-1

 

 

 

Standard Memory 80 MB

-2

Large Memory 200 MB

External Media

-4

CF Card (with Media) + USB

Language

-2

English/German/French

-4

Korean

Input Terminal

-1

Clamped Terminal

-2

Screw Terminal (M4)

Power Supply

-1

100V AC, 240V AC

-2

12V DC Note 1

-3

Rechargeable Battery Note 1

Power Cord

D

Power Cord UL/CSA Standard

F

Power Cord VDE Standard

R

Power Cord SAA Standard

Q

Power Cord BS/PSB Standard Note 11

H

Power Cord GB Standard

P

Power Cord EK Standard Note 10

W

Power Cord without AC Adapter Note 2

Options

 

 

/A1

Alarm Output 2 points Note 3

/A2

Alarm Output 4 points Note 3

/A3

Alarm Output 6 points Note 3

/A4

Alarm Output 12 points Note 3 and Note 4

/C2

RS-232 Interface Note 5

/C3

RS-422/485 interface Note 5

/F1

Fail/Status Output Note 4

/M1

Mathematical Functions

/N1

Cu10, Cu25 RTD input/3 leg isolated RTD

/N2

3 leg isolated RTD Note 6

/N3

Extended Input Type (PR40-20, Pt50, etc.)

/R1

Remote Control

/TPS4

24V DC Transmitter Power Supply (2 loops) Note 7

/PM1

Pulse Input Note 8

(including remote control and Maths function)

/CC1

Calibration Correction Function

/MC1

External Input Function Note 9

 
Note 1: An AC adapter is included as a standard accessory.
Note 2: 'W' can be specified for only 12V DC.
Note 3: /A1, /A2, /A3 and /A4 cannot be specified together.
Note 4: /A4 and /F1 cannot be specified together.
Note 5: /C2 and /C3 cannot be specified together.
Note 6: /N2 can be supplied for only MV2010, MV2020, MV2040 and MV2048.
Note 7: In case that /TPS4 is specified, /A4 cannot be specified together. And combination of /A3/F1
  cannot be specified together.
Note 8: In case that /PM1 is specified, /A4, /M1, /R1, and /TPS2 cannot be specified together.
  And combination of /A2/F1 and /A3/TPS4 cannot be specified together.
Note 9: MC1 can be specified for only MV2010, MV2020, MV2030, MV2040 and MV2048.
Note 10: In case that 100V AC, 240V AC is specified, 'P' cannot be specified together.
Note 11: BS standard is specified only 100V AC, 240V AC.
 
 
 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Tuesday, 15 November 2011