PC Based Data Acquisition

Model Type MX100
PC-Based Data Acquisition Unit Type MX100 - Features Page 1 of 5

Multi-Channel Capability
 
Measurement
interval
Maximum
number of
measurable
channels

Measurable
objects

PC Software Number of necessary modules (example)
MX100
Standard
Software
MXLOGGER

Main Module
(MX100)

Four channel
 High-speed
Universal Input Module
MX110-UNV-H04

Ten channel
Medium-speed
Universal Input Module
MX110-UNV-M10

10ms 24 channels DCV/TC/RTD/DI 1 6 -
50ms 24 channels DCV/TC/RTD/DI 1 6 -
50ms 120 channels DCV/TC/RTD/DI - 5 30 -
100ms 60 channels DCV/TC/RTD/DI 1 0 6
100ms 300 channels DCV/TC/RTD/DI - 5 0 30
200ms 500 channels DCV/TC/RTD/DI - 9 0 50
500ms 600 channels DCV/TC/RTD/DI - 10 0 60
1000ms 1200 channels DCV/TC/RTD/DI - 20 0 120
 

√ measurement that support is possible
- measurement that support is not possible


High Isolation Voltage

Reinforced insulation between the input terminal and the case handles 3700 Vrms for one minute, or 600 Vrms/VDC continuous. The relationship between measurement intervals and the number of channels largely depends on the performance of the PC. The actual performance may differ from that shown in the table.

PC System Requirements
CPU: Pentium 4 3.2 GHz; Memory: 1 GB; OS: Windows 2000; Hard disk: 160 GB; Communication interface: Ethernet 100Base-TX.
 

Multi-Interval Measurement

Three types of measurement intervals can be used in a single system in various combinations. Measurement intervals are specified for each module. It is also possible to set different types of input modules to the same measurement interval or to set the same type of input modules to different measurement intervals. Twelve measurement intervals are available as user-selectable options: 10 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, 30 s and 60 s. Please note, however, that measurement intervals of 10/50 ms cannot be set to the Medium-speed Universal Input Module (MX110-UNV-M10).

 

Examples of Setting Measurement Intervals
Multi-interval systems can be flexibly built for each module as shown in the figure below. Three colors color mark are used to indicate the three types of measurement intervals.






 


Examples of Setting Measurement Intervals

Monitor Window Using Yokogawa's Proprietary PC Software
The window shows measurement values by measurement intervals. Measurement can be performed while confirming rapidly-changing signals and slowly-changing signals simultaneously.

bullet

Measurement of sine waves at 0.5 Hz with a measurement interval of 100 ms

bullet

Measurement of sine waves at 8 Hz with a measurement interval of 10 ms

bullet

Measurement of sine waves at 1 Hz with a measurement interval of 50 ms

 

Monitor Window using the PC Software Developed by Yokogawa


 

Home | Amprobe | AVO/Megger |  Fluke | CIE | Yokogawa | Kyoritsu-Kew | Meterman | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
  14 Wright Street, Kewdale. Western Australia   6105   
                                                         
Phone: +61 8 9472 4444          Fax:+61 8 9472 4644

information@ledaelectronics.com.au

          Copyright © 2000 - 2008                                                                          Last Update: Saturday, 21 June 2008