Leda Electronics Logo. Western  Australia's largest distributor of Test Instruments Leda Electronics Showing The Way

 
Digital Oscilloscopes > SL1400 Features > Functions > Connectivity > Specifications > Model/Options
Yokogawa Test and Measurement Logo

Yokogawa Digital Oscilloscope Product Heading

SL1400 ScopeCorder LITE - Functions

Memory Backup Function
 

This function backs up about 150 hours of data saved to the acquisition memory immediately prior to power loss. Memory backup helps you avoid losing important data even if the power supply is unstable and gets cut off.

Backup time varies according to the usage environment. Four type 'AA' batteries are required for memory backup.


 

Memory Backup Function

Web Server Functions

Connect the SL14000 to your PC through the Ethernet connections. This allows for easy remote operation using a internet browser (e.g. Internet Explorer)
 

Web Server Functions

Having a wide range of triggers is of course very useful for obtaining the desired waveforms. In addition, the GUI menu makes setting trigger conditions easy and intuitive.
 
Simple and Enhanced Triggers
 
Simple and Enhanced Triggers
 
Wave Window Trigger
 

This function comes standard with the SL1400 and enable triggering on power supply waveforms. In addition to traditional power supply troubles, such as sudden outages, sags and surges, you can make efficient real time observations of frequency fluctuations and voltage drops.

This trigger activates when a signal exceeds the allowable values determined by comparing a defined waveform (wave window) with an actual waveform in real time.

Comparative waveforms can be automatically produced in real time based on measured waveforms. Detection on all 16 analog channels is available (with OR conditions).

Wave Window Trigger

 

 

 

 

 


 

 
Action-On Trigger (Automatically save measured data)

When this trigger is activated, the SL1400 performs a specified action each time a waveform is captured and displayed on the screen. This feature is useful for saving data automatically and reliably (e.g. for data collection in automated, continuous tests).

 
Manual Trigger (A trigger can be activated with the press of a button)
 
With this feature, a trigger can be executed whenever you like, independently from the set trigger conditions.

Manual Trigger

 
 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Tuesday, 15 November 2011