Model Suffix Code Description

701240
 

 

SL1400 main unit (16 isolated channel, 8 slots + 16-bit logic) Note1 with Built-in A4 thermal printer (210mm)

Power Cable Note2

-D

UL/CSA standard

-F

VDE standard

-R

AS standard

-Q

BS standard

-H

GB standard (Complied with CCC)

Internal Media Drive Note2

-J0

non Drive

-J3

PC card drive

Language Note2

-HE

English, English Panel

-HJ

Japanese, Japanese Panel

-HC

Chinese, English Panel

-HG

German, English Panel

-HF

French, English Panel

-HL

Italian, English Panel

-HK

Korean, English Panel

-HS

Spanish, English Panel

Options

/C8

Internal 40 GB hard drive (FAT32)

/C10

Ethernet option

/P4

Probe power (4-output)

 
Note1: Plug-in modules are not included.
Note2: Choose only one.
 
Standard Accessories supplied with Main Unit

Order Quantity

Description

One

Power cable (3-prong to 2-prong adapter included)

One

User's manual (one set)

One

Transparent front panel cover

One Roll

Printer paper, for DL750P and SL1400 (A4, 20 meter roll)

Eight

Cover panels (for empty module slots)

One Set

Rubber feet (four per set)

One

Soft case (for storing accessories)

 
 
 
Plug-in Modules

Model Number

Description

701250

High-speed 10 MS/s 12-bit Isolation Module (2 channels)

701251

High-speed 1 MS/s 16-bit Isolation Module (2 channels)

701255

High-speed 10 MS/s 12-bit non-Isolation Module (2 channels)

701260

High-speed 100 kS/s 16-bit Isolation Module (2 channels with RMS)

701261

Universal Module (2 channels)

701262

Universal Module (with anti-aliasing Filter, 2 channels)

701265

Temperature/high-precision voltage Module (2 channels)

701270

Strain Module (NDIS, 2 channels)

701271

Strain Module (DSUB, Shunt-CAL, 2 channels)

701275

Acceleration Module (with anti-aliasing Filter, 2 channels)

701280

Frequency Module (2 channels)

 
Note: Probes not included with any modules.
 
 

Model Number

Description Note1

700929

Isolated probe (10:1, 1000 Vrms CAT II for Modules 701250/51/60)

701940 Note2

Passive probe, non-isolated (10:1, 600 Vpk for Module 701255)

366926

1:1 BNC-Alligator cable (non-isolated 42V or less, for Module 701250/51/55), 1m

366961

1:1 Banana-Alligator cable (non-isolated 42V or less, for Module 701261/62/65) 1.2m

701933 Note3

Current probe (30 Arms, DC to 50 MHz, supports probe power)

701930 Note3

Current probe (150 Arms, DC to 10 MHz, supports probe power)

701931 Note3

Current probe (500 Arms, DC to 2 MHz, supports probe power)

701934 Note4

Power probe (large current output, external probe power supply) (4 outputs)

438920

Shunt resistor (250Ω ±0.1%, 4 to 20mA measurement)

438921

Shunt resistor (100Ω ±0.1%, 4 to 20mA measurement)

438922

Shunt resistor (10Ω ±0.1%, 4 to 20mA measurement)

700924

Differential probe (1400 Vpk, 1000 Vrms CAT II)

701955

Bridge head (NDIS 120Ω)

701956

Bridge head (NDIS 350Ω)

701957

Bridge head (DSUB, Shunt-cal 120Ω), with 5 meter cable

701958

Bridge head (DSUB, Shunt-cal 350Ω), with 5 meter cable

758924

Safety BNC-Banana adapter (500 Vrms CAT II, for Modules 701250/51/55/60)

701966

Printer paper (A4 size, 210mm x 20 meters), includes 6 rolls

702911 Note5

Logic probe (8-bit, non-isolated, TTL level/Contact Input) cable length 1 meter

702912 Note5

Logic probe (8-bit, non-isolated, TTL level/Contact Input) cable length 3 meters

700986 Note5

High-speed Logic probe (8-bit, non-isolated, response speed 1µs)

700987 Note6

Logic probe (8-bit, each channel isolated, response speed 20ms) (for AC)

758917

Isolated logic measurement leads (alligator clip required separately) (2 per set)

772090

CF Card adapter (required for CF cards)

772091

CF Card 128 MB

772092

CF Card 256 MB

366928

BNC (jack) to RCA (plug) conversion adaptor

701902

BNC safety cable (1000 Vrms CAT II), (BNC to BNC) cable length 1 meter

701903

BNC safety cable (1000 Vrms CAT II), (BNC to BNC) cable length 2 meter

701967

Soft carrying case (for SL1400, with 3 storage pockets)

 
Note 1: Actual allowable voltage is the lower of the voltages specified for the main unit and cable.
Note 2: 42 volts is safe when using the passive probe #701940 with an isolated type BNC input.
Note 3: The number of current probes shown are but a few of what  can be powered from the main unit.
Note 4: Any number of externally powered probes can be used.
Note 5: Includes one each of the B9879PX and B9879KX connection leads.
Note 6: Additionally, #758917 and either #758922 or #758929 are required for measurement.
 
 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Tuesday, 15 November 2011