This new addition to Yokogawa's highly recognized digital power analyzer product line offers innovative measurement functions which benefit the engineer with electrical power measurements. It is the ideal measurement solution for testing Product Efficiency, and the design of Inverters, Motor Drives, Lighting Systems, Uninterruptible Power Supplies, Aircraft Power Systems, Transformer Testing and other power conversion devices.
 

WT1800 Series - High Performance Power Analyzer

WT1800 Datasheet (PDF)
(documents are in PDF format and will open in a new window)

Features
  • Basic power accuracy ±0.1%.
  • DC power accuracy ±0.05%.
  • Voltage/Current bandwidth 5MHz (-3dB, typical).
  • Sample rate 2MS/s (16-bit).
  • Input elements maximum of 6.
  • Current measurements 100µA to 55A.
  • Fast data capture 5ms response (max. 1ms when external sync is ON).
  • All data of 6-inputs, single/three-phase devices can be viewed on a single 8.4 inch High Resolution XGA display screen.


General Specifications

 

Display

8.4-inch XGA display

Display Resolution

less than 60000 counts: 5 digits
more than 60000 counts: 4 digits

Display Sampling Rate

approx. 2MS/s

Number of Display Items

Select 4, 8, 16, Matrix, ALL, Harmonic Single List, Harmonic Dual List, Custom

Warm-up Time

approx. 30 minutes

Operating Temperature

5°C to 40°C (Humidity 20% to 80% R.H. non-condensation)

Storage Temperature

-25°C to 60°C (Humidity 20% to 80% R.H. non-condensation)

GP-IB Interface

conforms to IEEE Standard 488-2-1992

Ethernet Interface

conforms to IEEE802.3
Transmission Method: 1000BASE-T, 100BASE-TX, 10BASE-T

USB Interface

conforms to USB Rev. 2.0

   

Power Supply

100 to 120V AC / 220 to 240V AC

Rated Supply Frequency

50/60Hz

Power Consumption

150 VA max. (when using a built-in printer)

Battery Backup

Setting information and built-in clock continue to operate with a lithium backup battery.

Dimensions (excluding protrusions)

426mm (W) x 177mm (H) x 459mm (D)

Weight

approx. 15kg (including the main body, 6 input elements and options)

 

Models and Suffix Codes

Model

Suffix Code

Description

WT1800 Single Input Element

WT1801

-01

50A

 

-10

5A

WT1800 Two Input Elements

WT1802

-02

50A

50A

 

-11

5A

50A

-20

5A

5A

WT1800 Three Input Elements

WT1803

-03

50A

50A

50A

 

-12

5A

50A

50A

-21

5A

5A

50A

-30

5A

5A

5A

WT1800 Four Input Elements

WT1804

-04

50A

50A

50A

50A

 

-13

5A

50A

50A

50A

-22

5A

5A

50A

50A

-31

5A

5A

5A

50A

-40

5A

5A

5A

5A

WT1800 Five Input Elements

WT1805

-05

50A

50A

50A

50A

50A

 

-14

5A

50A

50A

50A

50A

-23

5A

5A

50A

50A

50A

-32

5A

5A

5A

50A

50A

-41

5A

5A

5A

5A

50A

-50

5A

5A

5A

5A

5A

WT1800 Six Input Elements

WT1806

-06

50A

50A

50A

50A

50A

50A

 

-15

5A

50A

50A

50A

50A

50A

 

-24

5A

5A

50A

50A

50A

50A

 

-33

5A

5A

5A

50A

50A

50A

 

-42

5A

5A

5A

5A

50A

50A

 

-51

5A

5A

5A

5A

5A

50A

 

-60

5A

5A

5A

5A

5A

5A

 

 

 

Standard Options

Power Cord

-D

UL/CSA standard

-F

VDE standard

-R

AS standard

-Q

BS standard

-H

GB standard

Languages

-HE

English menu

-HG

German menu

-HC

Chinese menu

 

 

 

Additional Options

Options

/EX1

External current sensor input for WT1801

/EX2

External current sensor input for WT1802

/EX3

External current sensor input for WT1803

/EX4

External current sensor input for WT1804

/EX5

External current sensor input for WT1805

/EX6

External current sensor input for WT1806

/B5

Built-in printer

/G5

Harmonic Measurement Note1

/G6

Simultaneous Dual Harmonic Measurement Note1

/DT

Delta Computation

/FQ

Add-on Frequency Measurement

/V1

RGB Output

/DA

20-channel DA Outputs

/MTR

Motor Evaluation Function Note2

/AUX

Auxiliary Sensor Inputs Note2

/HS

High Speed Data Capturing

 

Note1:

Select only one /G5 or /G6

Note2:

Select only one /MTR or /AUX

 

 

Note:

The numbers in the "Description" column have the following meanings:
50A: 50A input element, 5A: 5A input element
Elements are inserted in the order shown starting on the left side on the back.

 

 

 

GPIB, Ethernet and USB communication come standard with instrument

 

 

 

Adding input elements after initial product delivery will require rework at the factory. Please choose your models and configurations carefully, and inquire with your sales representative if you have any questions.

 

Home | Amprobe | CIE | EuroSMC | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
P.O. Box 1733 Malaga, LPO WA 6944
                                                      Unit 5, 31 Century Road, Malaga, Western Australia 6090                                                            
Phone: 61 8 9248 6688    Fax: 61 8 9248 6227

information@ledaelectronics.com.au

          Copyright © 2000 - 2011                                                                Last Modified: Tuesday, 15 November 2011